6
7
8
9
10
100

Which of the following switches has ON/OFF marked on the switch handle?

a.

None of the above

b.

Four way

c.

Three way

d.

Double pole

D. Double Pole

100

Type __________ cable is used for underground service entrance installations.

USE

100

In a parallel circuit, the total resistance is _____ value resistor.

less than the lowest

100

An accidental connection of a “hot” conductor and a grounded piece of equipment or the grounded conductor is called a(n) __________.

ground fault

100

Receptacle outlets must be installed in any wall space ____ or more in width.

24inches

200

When designing a home office, you could consider roughing in more wall receptacles than the NEC ____.

c.

minimum

200

What is the applied voltage in a series circuit with two resistors (25 V and 60 V, respectively)?

85 V

200

The NEC permits all bathroom receptacles to be on a single ____ branch circuit so long as it doesn’t supply other loads.

20-ampere

200

Which of the following is not a commonly used drill chuck size?

1/8 inch

200

With ____ products, it takes two failures to create a shock hazard to the user.

double-insulated

300

__________ are used to strip insulation, crimp solderless connectors, cut and size conductors, and cut and thread small bolts.

Multipurpose tools

300

Another name for a “Sawzall®” is a __________ saw.

reciprocating

300

A(n) __________ is a cutaway view that allows you to see the inside of a building.

sectional drawing

300

What piece of kitchen equipment is permitted to be connected to the two 20-ampere small-appliance circuits required for the kitchen and dining room area?

clock outlet

300

A receptacle outlet is a(n) ____.

outlet where one or more receptacles are installed

400

On construction sites, all 120-volt corded power tools must be plugged into a(n) __________.

ground fault circuit interrupter receptacle

400

Wiggy is an electrical trade name for a __________.

solenoid-type voltage tester

400

When a circuit has only one path, the _____ is the same at any point.

Current

400

CO/ALR marked on a receptacle indicates that __________ conductors may be terminated to it.

copper

copper-clad aluminum

400

are the most often used type of overcurrent protection device used in residential wiring

Circuit breakers

500

As defined in Article 100, a bathroom is required to have a ____.

basin

500

The statement, “In a DC circuit, the current is directly proportional to voltage and inversely proportional to resistance,” is know as _____ law.

Ohm's

500

A doorjamb switch is usually mounted about ____ above the floor, on the inside of the 2 x 4 framing on the hinge side of the closet door.

6 ft.

500

It is the __________ who has the job of approving the electrical materials used for a residential electrical installation.

authority having jurisdiction

500

Almost all 15 or 20-amp, 125-V receptacles required in a house must be __________.

tamper resistant

M