A voltage _____ is used to provide different voltages between certain points in a circuit.

divider

100

To avoid inductive heating in metallic raceways, the NEC requires that ____.

all circuit conductors be run in the same raceway

100

Lighting track in residential installations are not permitted to be installed less than ____ above a finished floor unless it is protected against physical damage, or if the track is of the low-voltage type operating at less than 30 volts rms open-circuit voltage

5'

100

If extra support is not to be provided, the mast service conduit must be not smaller than trade size ____ (metric designator 53) rigid metal conduit.

2

100

A __________ is used to deburr conduit, sharpen tools, and cut and form metal.

metal file

200

A bathroom is defined as "an area including a basin, with one or more of which items?

toilet

tub

bidet

any of these

any

200

A "unit switch" used as a disconnecting means for an electric clothes dryer shall ____.

disconnects all the conductors in the appliance

200

NEC 210.70(C) addresses ____ that are used for storage and attics that contain equipment that might need servicing, such as air-conditioning equipment.

attics

200

The neutral conductor is also referred to as the _____ conductor.

grounded

200

. A(n) __________ is a straight dashed line that is used to show the lines of an object that are not visible from the view shown in the plan

hidden line

300

A series circuit has a total resistance of 240 Ω and a current flow of 4 A. What is the applied voltage?

960v

300

Recessed lighting fixtures constructed for installation in thermal insulation are rated as ____.

Type IC

300

A popular type of drill bit, used for precise, repetitive drilling though a variety of tough materials, is called a

step bit

300

Which of the following test instruments must be used only when the circuit in not energized?

Ohmmeter

300

When an existing dryer or electric range is replaced, the NEC ____ the grounded conductor of an existing individual branch circuit to be used for grounding the appliance frame.

permits

400

Parallel circuits are also referred to as _____.

Current dividers

400

Kitchen lighting ____ permitted to be supplied by the two 20-ampere small-appliance circuits required for the kitchen and dining room area.

is not

400

NEC 410.10(D) ____ lighting track to be located within a zone measured 3 ft (900 mm) horizontally and 8 ft (2.5 m) vertically from the top of a bathtub rim or top of a shower stall threshold.

does not permit

400

Lighting track in residential installation ____ permitted to be installed in the zone 3 ft horizontally and 8 ft vertically from the top of a bathtub rim.

are not

400

A(n) ____ receptacle can be hidden behind a painting or photograph that you want to light up.

clock hanger

500

A(n) __________ shows the side of the house that is facing a certain direction.

elevation drawing

500

A T12 fluorescent lamp is ____ inch(es) in diameter and a T8 is ____ inch(es).

1-1/2", 1"

500

Residential wiring plans generally show lighting and receptacle outlet locations but not circuits. The electrician should design the installation with which of the following in mind?

National Electrical Code requirements

economy-minimizing the number and length of circuits

convenience for the homeowner or other user

all of these

all of these

500

__________ are used to cut cables and conductors in a limited space.

Diagonal pliers

500

A series circuit has two resistors that dissipate 10 W and 15 W, respectively. What is the total power dissipation of the circuit?

25W

M
e
n
u