What are the 4 types of switches?

single-pole, double-pole, 3-way, 4-way

100

Who is the first superhero to appear in the Marvel Cinematic Universe?

Iron Man Tony Stark

100

What color must the identified grounded conductor be?

white or grey

100

You have a hallway that is 12 foot long is it a requirement that at least 1 receptacle be installed?

Yes

100

True/False When 2 Type NM-B cables enter a box it is not permitted to bring both of the bare wires to the grounding terminal without splicing or pigtailing.

True

200

What terminal on a 3-way switch do you connect the red traveler?

Brass

200

True/False you can use the uninsulated conductor for other purposes instead of just for grounding.

False

200

In Monsters, Inc., how many total legs does the camouflaging villain Randall Boggs have?

8

200

What unit of measurement is used for the diameter of wires?

Mils

200

What is the largest size solid conductor permitted to be installed in a raceway? Where in the code book can you find this information?

10 AWG 310.3(C)

300

Where in the NEC would you find the table for the cross-sectional area circular mils? 

Chapter 9 table 8

300

The type most commonly used for residential wiring projects "ac only" general snap switches. What are they marked by for the identity of the switch?

Voltage and current ratings

300

What is the maximum overcurrent protection you can use when using 12AWG

20amp

300

Wire connectors marked AL/CU are suitable for use with?(Multi answers)

Copper Aluminum Copper-Clad

300

In The Jungle Book, what kind of animal is Bagheera

Black panther

400

According to table 310.4 can XHHW be used in wet and dry locations? If so what are the maximum temperatures? 

Yes Dry 90 Wet 75

400

Does types NM and MC require a grounded conductor at switch locations?

Yes

400

True/False Using the bare grounding wire as a substitute for the neutral conductor is a common allowed practice.

False

400

In Superbad, what is the single name printed on Fogell’s fake ID?

McLovin

400

When looking at the voltage drop formula where would you use the value for the cross-sectional are?

CMA

500

In The Matrix (1999), what color pill does Neo take to learn the truth about the Matrix?

The red pill

500

Given these components will your single gang box stamped with 20.3 cu inches have ample room to meet code? 

(1) 3-way switch

(1) 14/2

(1) 14/3

Yes 

500

A 480-volt branch circuit supplies a resistive heating load of 50 amperes. The distance from the panel to the heater is 100ft. calculate the voltage drop to determine the minimum size wire to be installed. 

10 AWG

500

What switch rating is required to control 4 300-watt tungsten filament lamps on a 240-volt circuit?

5

500

A 45-ampere individual branch circuit is installed for an electric clothes dryer. What is the maximum ampere rating of a dryer permitted by the NEC to be cord and plug connected circuit?

36