Numbers Never Lie
Ground Fault your'e Out!
Brady Branch
Chapter of my life?
Terms of Endearment
100

What is the maximum trade size for electrical metallic tubing

4 inch EMT

100

T/F,  According to code, GFCI protection is required in all living dwelling spaces of a home.

False, only required in what is considered a wet and or damp location.

100

The rating of a Branch Circuit is determined by the rating of the

branch- circuit overcurrent protection aka Circuit Breaker

100

In which chapter of the NEC can I find the Definitions

Chapter 1

100

Actual terminology for a light or lighting fixture in the NEC

luminare

200

What is the minimum Electrical Trade Size for Rigid Metallic Conduit

1/2 inch RMC

200

T/F, By code,  GFCI protection is required everywhere AFCI protection is required.

False

200

If I calculate 17A on a corcuit, what size Over Current Circuit Device should I install

20A

200

This chapter is associated with purely mostly ultimately only Tables

Chapter 9 Annex

200

Actual terminology for pipe in NEC

RACEWAY

300

The largest trade size for conduit, tubing, and associated fittings and accessories is

6 inch

300

What is the maximum height allowed for a duplex receptacle to count as an outlet in a residence?

5 1/2 feet

300

For all Kitchen countertop receptacles what is the maximum distance between each receptacle?

48 inches or 4 feet

300

Which article in chapter 2 covers overcurrent protection/

Article 240

300

Actual terminology for Hot Wire in the NEC

Ungrounded Conductor

400

The maximum Electrical Trade size for rigid polyvinyl chloride conduit is

6 inch

400

When does the equipment grounding conductor conduct current

When a fault occurs. (This will allow high current and therefore trip the overcurrent device)

400

T/F By exception you can supply both Kitchen Lighting and Receptacle power on same Branch Circuit

False

400

What does article 250 in NEC cover?

Grounding 

400

Actual Terminology for the Green or copper wire

Equipment Grounding Conductor

500

What is the height of an Electrical Meter measuring from the finished grade to center 

60 inch max,48" min

500

GFCI protection for personnel is required for all 15 and 20A, 125v single-phase receptacles installed in a dwelling unit such as

a) living room

b) attic

c) garage

d) all of these

c) garage is the only of these that require  GFCI protection

500

When running a 120v circuit and calculating 20A for an individual circuit, what is the total VA rating for that particular Branch circuit

2,400 VoltAmps

500

Which of these is not covered in Chapter 8 of the National Electrical Code book 2014 edition?

a) Fiber Optics

b) Community Antenna Television

c) Grounding and Bonding

d) all of the ablove

Grounding and Bonding

500

The purpose of the National Electrical Code book is a manual for designing your electrical system

•Purpose

–The NEC® is a safety manual

–A minimum safety standard

–90.1 (A) Practical Safeguarding

–Persons and property from the hazards of electricity

        (B) Adequacy

–Installations that are essentially free from hazard

            (C) Intention

–The Code is not to be used as a design specification or as an instruction manual