Parameters
Artifacts
Producing Quality MRI Images
MRI Protocols
Policies and Procedures
100

Typically, an MRI image's resolution is controlled by this.

What is Matrix?

100

This artifact occurs when you increase slice thickness "too much".

What is Partial Volume Averaging?

100

Reducing our FOV, causes our Signal-to-Noise to do this.

What is decreasing SNR?

100
When scanning a whole body, we set the cross hairs of our localizer at this location.

What is the top of the head?

100

When setting up for most iMRI intraOp procedures, we do this to warm up the MRI scanner table hours before the patient is transferred on to our MRI table.

What is use a "bear hugger" to warm the surface of the table?

200

This parameter is largely responsible for the T2-weighting of an MRI Image

What is TE (Time to Echo)? 

200

This type of sequence, most common in Neuro and MSK imaging, is a common solution for motion artifacts.

What is PROPELLER imaging?

200

When selecting a coil for any exam where multiple coils are an option, it is best to select these coils.

What is smaller coils with higher channels?

200

When scanning an abdomen / pelvis tumor protocol, this can be a "backup sequence" to the Cor Vol T2 RTr.

What is a BH SSFSE T2, ST=4, SS=-2?

200
These individuals are being changed into MRI safe gowns that will experience the gradient magnetic field.

Who are everyone?

300

This parameter is a combination of acquisitions.

What is NEX (Number of Excitations)?

300

When scanning a Pancreas (Freq, Dir,: R>L), in order to reduce the pulsatile motion from the abdominal aorta, we would place a saturation band in this location relative to the prescribed slices.

What is superior to the prescribed slices?

300

When an awake patient with a sporadic breathing waveform cannot properly perform the required breathing instructions and RTr is not producing high quality images this is your best bet.

What is Navigation? or What is Manual Trigger (SSFSE)?

300
Excluding the planes, what sequences are included in a Brain Lab protocol?

what is DTI, 3D T1 and T2 CUBE?

300

When scanning a fetus, the mother should take a valium at this time before the first image is acquired.

What is 15 minutes before acquiring the first MR  image?

400

When scanning an axial plane of the thoracic spine, we need the frequency in this direction to reduce aliasing.

What is the R/L direction?

400

This artifact arises from stimulated echoes picked up outside the FOV by distant array coils that have not been properly deactivated.

What is annefact (cusp) artifact?

400

Using parallel imaging or increasing the acceleration of parallel imaging will do this to your SNR.

What is decrease SNR?

400

If you have a question regarding a protocol, QA or anything else that is related to the scanner, imaging or protocols, reach out to these individuals first.

Who are the Clinical Instructors?

400

We should be referring to this website during every single MRI exam to ensure that all directions are followed and all sequences are accounted for.

What is MedWiki?

500

When the parameters of a specific sequence seem incorrect, corrupt or their is an error of any kind, you should do this first.

What is bring over another comparable sequence from another protocol or pull from GE.

500

Susceptibility artifact is directly proportional to these two MRI parameters.

What is B0 and TE?

500

DAILY DOUBLE: This is the equation for scan delay.

what is (scan time / 2)+[(contrast/2)x flow rate]?

500

If Medwiki and a Protocol has a conflict, this should be followed.

What is MedWiki?

500

During a Code (not at 732), what extension do we call and what information do we provide to the operator?

What is extension 211? and, what is the room number and whether the patient is pediatric or adult (18yo+)?