100

How long is our rule of thumb when pulling wire?

6 in

100

True/False You should consider yourself safe when working with low voltage.

False

100

When entering or leaving a box your Romex should be secured how far from top or bottom?

8 in
100

What is gold?

Hot

100

314.16 is used for what calculations?

box fill

200

What unit is abbreviated by F?

Farad

200

True/False When computing a load you include open porches in the floor area.

False

200

What is stamped inside boxes?

Volume

200

Where are 15-amp circuits required?(Multiple possible answers)

Bathrooms, front entries, bedroom lighting, hall lighting

200

Every how many feet should your Romex be secured?

4 1/2ft

300

Where are specific heights for receptacles and switches often required?(multiple answers)

countertops

300

Did our circuit last night have an open or a short? 

Open 

300

Are switched lighting outlets or receptacles required in bathrooms and hallways?

Yes

300

a wall receptacle should be placed no longer than how far apart running horizontally?

6ft

300

NEC 90.9(C)(1) states that is the measured size of a product is not the normal size the _____ shall be used rather than dimensions.

Trade size designator

400

What does the rating of the over current device determine?

the rating of a branch circuit

400

True/False a weather-resistant receptacle should be installed in any outdoor wet or damp area?

True

400

When using a ladder to perform overhead work near house service drops or weatherheads, the ladder must be made of this non-conductive material

Fiber-glass

400

When calculating your box fill and you have 11 grounds what is your total number for your grounds?

2.75

400

Where would you look to find the conductor ampacity? 

310.16

500

According to NEC 314.16 boxes should be large enough to provide?

ample room

500

If have an occupied square footage of 11.220 in a dwelling what is your minimum number of lighting branch circuits? 

19

500

Using a 2 gang non-metallic box stamper with 38 cu inches giving these components will you have enough volume within the box to meet code?

(1) Single pole switch (1) 3 way switch

(3) 12/2 (2) 12/3

No 38.25

500

This dangerous condition occurs when a hot conductor makes direct contact with a grounded metal box or neutral path, causing an immediate overcurrent surge

Short circuit

500

What is the minimum number of 15-amp lighting branch circuits required in the occupied square footage of the dwelling is 4700ft?

8