100

A live-dead-live test is used to verify

that a circuit is de-energized

100

Residential electrical services are grounded by connecting the grounded conductor to a grounding electrode at the

neutral bus in the main panelboard

100

A PFAS anchorage point for a 6-foot lanyard must be able to hold

5000lbs

100

An electrical drafting line with a double arrowhead represents.

 a Homerun

100

What is the total resistance in a series circuit with three resistances of 20Ω, 150Ω, and 10Ω.

45 ohms

200

The load on a branch circuit should not exceed _____% of its rated capacity.

80%

200

True or False: The neutral conductor is always larger than the ungrounded conductors

False

200

What is the proper distance from the feet of a straight ladder to the wall?

one-fourth of the working height of the ladder

200

The symbols T1 T2 and T3 in a typical motor starter schematic represent

Motor Terminals

200

What is the formula for calculating the total resistance in a series circuit with three resistors is

Rt= R1+R2+R3

300

If a floor plan of a building is drawn to a scale of 1/8" = 1' - 0", a distance of 1-3/8" on the drawing would equal

11' - 0" on the building itself

300

Which conductor is grounded on a single­ phase, three-wire, 120/240V system?

Neutral

300

Asbestos was banned in ________ ; therefore, you must assume that any facility constructed before ___________has asbestos in it.

1978;1980

300

Power-riser diagrams are used to show the

arrangement of electric service equipment

300

Kirchhoff's voltage law states that the algebraic sum of the voltages around any closed current path is

Zero

400

A conflict between the drawings and the specifications is resolved by

Change Order

400

Which of the following is an NEC' violation when used as a grounding electrode

Underground gas line
400

What are the minimum and maximum distances (in inches) that a scaffold plank can extend beyond its end support?

6'';12''

400

True or False: A branch circuit line or drawing that does not have slashes is assumed to have two conductors

True

400

In  a parallel circuit, the voltage across each path is equal to the

applied voltage

500

 Who stated that the current entering a point must equal the total current leaving that point

Kirchhoff

500

What is used to connect a ground rod with a grounding electrode conductor?

A Grounding Clamp

500

What applies in a lockout/ tagout procedure?

Lockout/tagout devices are installed by every authorized employee involved in the work

500

The current MasterFormat® standard covering communications systems is under

Division 27

500

The number of cycles an alternating electric current undergoes per second is known as

frequency