Dolphin
Sail Fish
Grouper
Marlin
Tuna
100

What agency is responsible for the maintenance and publication of the NEC?

NFPA

100

Formal interpretations of the NEC are governed by ____?

NFPA

100

The UL logo indicates that _____?

the listed product complies with UL standards

100

The word luminaire refers to ____?

a complete lighting unit
100

An _____ is the organization, office, or individual responsible for enforcing the requirements of a code.

AHJ

200

T/F:  All dolphins are saltwater fish

False:  The amazon river is home to 4 species of river dolphins that are found no where else on earth.

200

What is the top speed of a sailfish?  (within 5mph)

70 mph

200

Some species of grouper can weight more than...

a. 300lbs

b. 500lbs

c. 800lbs

d. 1000lbs

d.  1000lbs

200

Marlin was the name of Nemo's dad.  What kind of fish was Marlin?

clownfish

200

What is the name of StarKist brand tuna mascot?

a. Fred

b. Charlie

c. Tony

d. Hank 

b. Charlie
300

A contact device installed at an outlet for the connection of an attachment plug is a(n) _____?

receptacle

300

What is the angle pull for a raceway in the vertical dimension where the trade size of the largest raceway is 4 and sum of the other raceways in the same row on the same wall is 5?

29 inches

300

What is the angle pull for a raceway in the horizontal dimension where the trade size of the largest raceway is 3 and the sum of the other raceways in the same row on the same wall is 4?

22 inches

300

A service point can be described as the point of demarcation between where the ____ ends and the premises wiring begins.

serving utility

300

The NEC arose as a consensus of more than 1200 individuals primarily to _____?

combat growing epidemic of electrical fires

400

The NRTL program specified in the Code of Federal Regulations _____?

accredits and regulates independent laboratories

400

Nonmetallic-sheathed cable not fastened to the box must be secured within ____ in. of the box?

8 inches

400

A load having the maximum level of current sustained for 3 hours or more is referred to as a ____ load?

continuous

400

Multiconductor cord or cable used to support a box must be protected in an approved manner so that the conductors are not subjected to _____?

strain

400

The length of a straight pull for multiple raceways must be at least ____ times the trade size of the largest single raceway.

eight

500

A 3x2 in. device box, 2.5 in. deep, has a volume of _____ cubic inches?

12.5 

500

Mandatory rules in the NEC contain the language _____?

Shall and Shall Not

500

A(n) ____ is a device intended to provide protection from the effects of arc faults by recognizing characteristics unique to arching.

arc-fault circuit interrupter

500

An appliance branch circuit supplies energy to one or more outlets for the purpose of _____?

connecting appliances

500

All conductors of a multiwire branch circuit must originate from ____?

the same panelboard or similar distribution equipment

M
e
n
u