Article 90 Introduction and Article 100 Definitions
Article 110 General Requirements for Electrical Installations
Chapter 2 Wiring and Protection
Chapter 3 Wiring Methods and Materials
Chapter 4 Equipment for General Use
100

Electrically connected to or is a source of voltage.

What is Energized, Article 100?

100

This article states that equipment intended to interrupt current at fault levels shall have an interrupting rating at nominal circuit voltage at least equal to the available fault current at the line terminals of the equipment

What is Article 110.9 Interrupting rating?

100

An insulated conductor that is intended for use as a grounded conductor, where contained within a flexible cord, shall be identified by a white or gray outer finish or by methods permitted by 400.22

What is Article 200.6(C) Flexible Cords?

100

Backfill that contains large rocks, paving materials, cinders, large or sharply angular substances, or corrosive material shall not be placed in an excavation where materials might damage raceways, cables, conductors, or other substructures or prevent adequate compaction of fill or contribute to corrosion of raceways, cables, or other substructures

What is Article 300.5(F) Backfill?

100

Where cords and cables are used in ambient temperatures other than 30°C (86°F), the temperature correction factors from Table 310.15(B)(1)(1) that correspond to the temperature rating of the cord or cable shall be applied to the ampacity in Table 400.5(A)(1) and Table 400.5(A)(2).

What is Article 400.5(A) Ampacity Tables?

200

Rules of this Code that identify actions that are specifically required or prohibited and are characterized by the use of the terms shall or shall not.

What are Mandatory Rules, Article 90.5(A)?

200

Unless identified for use in the operating environment, no conductors or equipment shall be in damp or wet locations, where exposed to gases, fumes, vapors, liquids, or other agents that have a deteriorating effect on the conductors or equipment; or where exposed to excessive temperatures.

What is Article 110.11 Deteriorating Agents?

200

No grounded conductor shall be attached to any terminal or lead so as to reverse the designated polarity.

What is Article 200.11 Polarity of Connections?

200

Where the installation complies with the special requirements specified in 645.4, electrical wiring in air-handling areas beneath raised floors for information technology equipment shall be permitted in accordance with 645.5(E).

What is Article 300.22(D) Information Technology Equipment?

200

Double-throw knife switches shall be placed so that the throw is either vertical or horizontal.

What is Article 404.6(B) Double-Throw Knife Switches?

300

Rules of this Code identify actions that are allowed but not required. These are normally used to describe options or alternative methods and are characterized by the use of the terms shall be permitted or shall not be required.

What are Permissive Rules, Article 90.5(B)?

300

According to this article, the permanent outer finish of a high-leg conductor must be orange in color.

What is Article 110.15 High-leg Marking?

300

For the purposes of this section, the distance from receptacles shall be measured as the shortest path the power supply cord connected to the receptacle would follow without piercing a floor, wall ceiling, or fixed barrier.

What is Article 210.8 Ground-Fault Circuit-Interrupter Protection for Personnel?

300

The conductor shall not be bent to a radius less than 8 times the overall diameter for nonshielded conductors.

What is Article 305.5 Conductor Bending Radius?

300

Except as provided in 406.4(D), receptacles installed on 15- and 20-ampere branch circuits shall be of the grounding type. Grounding-type receptacles shall be installed only on circuits of the voltage class and current for which they are rated…

What is Article 406.4(A) Grounding Type?

400

Power conversion equipment that adjusts the speed of an electric motor.

What is an Adjustable Speed Drive, Article 100?

400

Specified as within sight from or within sight of another equipment the specified equipment shall be visible and not more than 15 m, or 50 ft distant from the other

What is Article 110.29 In Sight From (Within Sight From, Within Sight)?

400

In no case can the load exceed the branch-circuit amp rating.

What is Article 210.23 Permissible Loads, Multiple-Outlet Branch Circuits?

400

In damp or wet locations, surface-type enclosures within the scope of this article shall be placed or equipped so as to prevent moisture or water from entering and accumulating within the cabinet or cutout box, and shall be mounted so there is at least 6-mm (1/4 in.) airspace between the enclosure and the wall or other supporting surface.

What is Article 312.2 Damp or Wet Locations?

400

A recessed luminaire that is not identified for contact with insulation shall have all recessed parts spaced not less than 13 mm (1/2 in.) from combustible materials.

What is Article 410.116 (A)(1) Non-Type IC?

500

Electrical device that converts single phase power to three phase electric power.

What is a phase converter, Article 100?

500

Manhole covers shall have an identifying mark or logo that prominently indicates their function such as electric.

What is Article 110.75(E) Marking?

500

SPDs and surge arresters shall not be reconditioned.

What is Article 242.2 Reconditioned Equipment?

500

Suitable bushings, shields, or fittings having smooth, rounded edges shall be provided where conductors or cables pass through partitions and at other locations where necessary.

What is Article 314.72(B) Passing Through Partitions?

500

The residual voltage of a capacitor shall be reduced to 50 volts, nominal, or less within 1 minute after the capacitor is disconnected from the source of supply.

What is Article 460.6(A) Time of Discharge?