100

Electric-discharge luminaires having an open-circuit voltage

exceeding __ shall not be installed in or on dwelling occupancies.

1000 Volts--   Art 410.140-B

100

Knife switches rated for more than 1,200A at 250V or less __ .

can be used only as isolating switches and shall not be opened under load

ART 404.13 A

100

Where Type Ml cable terminates, a(n) __ shall be installed

immediately after stripping to prevent the entrance of moisture

into the insulation.

end seal fitting   ART 332.40 B

100

A conductor used for open wiring on insulators that penetrates

a wall, floor, or other framing member shall be carried through

a  ______.

separate sleeve or tube    ART 398.17

100

Mandatory NEC rules are those that identify actions

that are specifically required or prohibited and are

characterized by the use or the terms __ .

Shall or Shall not  Art 90.5 A

200

Lampholders shall be constructed, installed, or equipped with

shades or guards so that __ is not subjected to temperatures

in excess of 90°C (194°F).

combustible material ----- 410.97

200

Electrical service equipment at carnivals and circuses shall not

be accessible to unqualified persons, unless _ _ .

lockable   Art 525.10 A

200

Receptacles, receptacle housings, and self-contained devices

used with flat conductor cable systems shall be __ .

identified for this use     ART 324.42 A

200

When the service disconnecting means is a power-operated

switch or circuit breaker, it shall be able to be opened by hand

in the event of a  ____. 

power supply failure   ART 230.76-2

200

Kitchen countertop receptacle outlets shall be

installed so that no point along the wall line is more

than ___ in., measured horizontally from a recep·

tacle outlet in that space.

24 inches  ART 210.52 C 1

300

Nonmetallic surface extensions shall be secured in place by

approved means at intervals not exceeding _ _ in.

8 inches  --- 382.30 A

300

Short sections of metal enclosures or raceways used to provide

support or protection of __ from physical damage shall not be

required to be connected to the equipment grounding conductor.

cable assemblies   250.86  EX 2

300

Where insulated conductors are deflected within a metal wireway,

the wireway shall be sized to meet the bending requirements

corresponding to _ _ wire per terminal in Table 312.6(A).

one    ART 376.23 A

300

Cable wiring methods shall not be used as a means of support

for _____. 

other cables, raceways and nonelectrical equipment   Art 300.11 D

300

Where an equipment bonding jumper is installed on

the outside of a raceway, the length shall not exceed

_ ·-··- ft and shall be routed with the raceway or

enclosure.

6     Art 250.102. E -2

400

Coaxial cables used for CATV systems shall not be strapped,

taped, or attached by any means to the exterior of any __ as

a means of support.

conduit or raceway --- ART 820.133 B

400

When a building is supplied with a(n} _ _ fire sprinkler system,

ENT shall be permitted to be used within walls, floors, and

ceilings, exposed or concealed, in buildings exceeding three

floors above grade.

NFPA 13    ART 362.10-2 EX2

400

On a three-phase, 4-wire, delta-connected service where the

midpoint of one phase winding is grounded, the service conductor

having the higher phase voltage-to-ground shall be durably and

permanently marked by an outer finish that is __ in color, or

by other effective means, at each termination or junction point.

orange    ART 230.56

400

In dwelling units, hallways of ____ ft or more in

length shall have at least one receptacle outlet.

10 feet ART 210.52 H

400

Conductors shall be considered outside of a building

or other structure where installed under not less

than __ in. of concrete beneath a building or

other structure.

2 inches Art 230.6

500

A receiving station outdoor wire-strung antenna conductor with

a span of 75 ft shall be at least __ AWG if a copper-clad steel

conductor is used.

17 ----- ART 810.16 A and table

500

A demand factor of __ percent applies to a multifamily dwelling

with ten units if the optional calculation method is used.

43%   220.84 and table

500

Conductors located above an electric space-heated ceiling are

considered to be operating in an ambient temperature of __ .

50°C   ART 424.36

500

Service conductors installed as open conductors

shall have a clearance of not less than ft from

windows that are designed to be opened,

3 feet   ART 230.9-A

500

In all areas specified in 210.52, all nonlocking-type

125-vo\t, 15- and 20-ampere receptacles shall be

listed tamper-resistant receptacles  ART 406.12