NEC DEFINITIONS
NEC DEFINITIONS
NEC DEFINITIONS
NEC DEFINITIONS
NEC DEFINITIONS
100
The circuit conductors between the final overcurrent device protecting the circuit and the outlets
Branch circuit
100
Equipment or materials to which has been attached a label, symbol, or other identifying mark of an organization that is acceptable to the authority having jurisiction and concerned with product ealuation, that maintains periodic inspection of production of labeled equipment or materials and by whose labeling the manufacturer indicates compliance with appropriate standards or performance in a specified manner
Identified
100
Equipment, materials, or services included in a list published by an organization that is acceptable to the authority having jurisdiction and concerned with evaluation of products or services that maintains periodic inspection of production of listed equipment or materials or periodic evaluation of services and whose listing states that the equipment, material or servies either meets appropriate designated standards or has been tested and found suitable for a specified purpose
Listed
100
Recongnizable as suitable for the specific purpose, function, use, environment, application and so forth, where described in a paticular Code requirement
Identified
100
A conductor used to connect equipment equipment or the grounded circuit of a wiring system to a grounding electrode or electrodes
Grounding conductor
200
All circuit conductors between the service equipment, the source of a separtely derived system, or other power supply source and the final branch circuit overcurrent device
Feeder
200
The permanent joining of metallic parts to form an electrically conductive path that ensures electrical continuity and the capacity to conduct safely any current likely to be imposed
Bonding
200
A system or circuit conductor that is intentionally grounded
Grounded conductor
200
The current , in amperes, that a conductor can carry continuously under the conditions of use without exceeding its temperature rating
Ampacity
200
Acceptable to the authority having jurisdiction
Approved
300
Capable of being reached quickly for operation, renewal, or inspections without requiring those to whom ready access is requisite to climb over or remove obstacles or to resort to portable ladders, and so forth
Accessible, readily
300
The conductor used to connect the non current carrying metal parts of equipment, raceways, and other enclosures to the system grounded conductor, the grounding electrode, or both, at the service equipment or at the source of a separtely derived system
Grounding Conductor, Eq.
300
Intentionally connected to earth throuhg a ground connection or connections of sufficiently low impedance and having sufficient current carrying capacity to prevent the build up of voltages that may result in undue hazards to connected equipment or to persons
Grounded, effectively
300
Where this code specifies that one equipment shall be "in sight from", "within sight from" or "within sight" and so forth of another equipment, the specified equipment is to be visible and not more than 15m (50 ft) distant from the other
In Sight From
300
A circuit, other than field wiring, in which any arc or thermal effect produced under intended operating conditions of the equipment is not capable, under specified test conditions, of igniting the flammable gas-air, vapor-air, or dust-air mixture
Nonincendive circuit
400
A device or group of devices that serves to govern in some predetermined manner, the electric power delivered to the apparatus to which it is connected
Controller
400
A switch rated in the horsepower that is capable of interrupting the maximum operating overload current of a motor of the same horsepower rating as the switch at the rated voltage
Motor circuit switch
400
A switch intended for isolating an electric circuit from the source of power. It has no interrupting rating, and it is intended to be operated only after the circuit has been opened by some other means
Isolating switch
400
A Device, or goup of devices, or other means by which the conductors of a circuit can be disconnected from theri source of supply
Disconnecting means
400
The highest current at rated voltage that a device is inteded to interrupt under standard test conditions
Interrupting rating
500
A device designed to open and close a circuit by nonautomatic means and to open the circuit automatically on a predetermined overcurrent without damage to itself when properly applied wihin its rating
Circuit breaker
500
Indicates that the motor is provided with a thermal protector
Thermally protected
500
A protective device for assembly as an integral part of a motor or motor compressor that when properly applied protects the motor against dangerous overheating due to overload and failure to start
Thermal protector
500
Any current in excess of the rated current of equipment or the ampacity of a conductor. It may result from overload, short circuit or ground fault
Overcurrent
500
Operation of equipment in excess of normal, full load rating, or of a conductor in excess of rated ampacity that, when it persists for a sufficient length of time, would cause damage or dangerous overheating.
Overload A fault, such as a short circuit or ground fault, is not an overload.
M
e
n
u