Article 210
Article 250
Article 230
Article 310
General Knowledge
100

This article covers what type of circuits?

Branch Circuits

100

Which article covers grounding and bonding?

Article 250

100

What article covers electrical services?

Article 230



100

Which article contains conductor ampacity tables?

Article 310

100

Generally, how often is the NEC revised?

Every 3 years


200

Which receptacles in dwelling bathrooms require GFCI protection?

All 125V though 250V receptacles

200

What color identifies an equipment grounding conductor?

Green or bare

200

Where is the service disconnect required to be located?

Readily accessible and nearest the point of entrance of the service conductors.

200

What is the ampacity of #12 copper THHN at the 90 degree column?

30 Amps

200

What do the letters "NEC" stand for?

National Electrical Code

300

What is the maximum breaker size protecting #12 copper conductors under normal conditions?

20 amps

300

What is the purpose of bonding?

To establish an effective fault-current path.

300

What is the purpose of a service disconnect?

To disconnect all power to the building

300

Why can't you always use the 90 degree ampacity?

Because equipment termination temperature ratings often limit the allowable ampacity.

300

Who publishes the NEC?

The National Fire Protection Association (NFPA)

400

How many small-appliance branch circuts are required in a dwelling kitchen?

Two 20amp circuits

400

Name two acceptable grounding electrodes.

Ground rod, Concrete-encased electrode (Ufer), Building steel, Metal underground water pipe

400

True or False:

The grounded (neutral) conductor may be disconnected before the undergrounded conductors.

False

400

What happens to conductor ampacity when more than three current-carrying conductors are installed in the same raceway? 

It must be derated.

400

What chapter contains wiring methods?

Chapter 3

500

Name three locations requiring GFCI protection in a dwelling

Bathrooms, Kitchens, Garages, Outdoors, Crawl spaces, Basements, Laundry areas 

500

What is the minimum lenght of a ground rod driven into the earth?

8 Feet

500

How many service disconnects are generally permitted for each service?

One, unless otherwise permitted by the NEC.

500

Name two factors that affect conductor ampacity.

Ambient Temp, Number of current-carrying conductors, Insulation Type, Conductor material (copper/aluminum)

500

Name all nine chapters of the NEC

1 General, 2 Wiring and Protection, 3 Wiring Methods and Materials, 4 Equipment for General Use, 5 Special Occupancies, 6 Special Equipment, 7 Special Conditions, 8 Communications Systems, 9 Tables