PRP/PRP Eligibility Extension
Special Certificates
Lowest Floor Elevation
Rating
Potpourri
100
$1,000
What is the standard deductible that applies to all PRP's?
Or
What is the only deductible option for a PRP?
100
Buildings in an AE, A1-A30, VE, V1-V30 must have their Elevation Certificates completed by one of these people.
Who is a licensed surveyor, engineer or architect?
Or
Who is a land surveyor, engineer or architect who is authorized by state or local law?
100
When rating a slab foundation, this floor is used as the Lowest Floor Elevation when the Machinery & Equipment located here is below the Base Flood Elevation and the area is not properly vented.
What is the attached garage floor?
100
$50
What is the Probation Surcharge?
100
The more hazardous zone.
Which flood zone is used when presented with 2 different flood zones?
200
RCBAP & Buildings located in the Emergency Program.
What are ineligible PRP Risks?
200
Sections A, B, E & F of the Elevation Certificate.
What are the sections of the Elevation Certificate that the property owner or owner's representative can complete for an AO Zone or an Un#A without a Base Flood Elevation?
200
The lowest floor for rating when any of the following conditions exists:
The enclosed space is finished;
Or the unfinished enclosed space is used for other than building access, parking or storage;
or the unfinished enclosed space has no proper openings.
What is the enclosure floor?
Or
What is C2a?
Or
What is the top of the bottom floor?
200
The rates used when the lowest floor goes below the Lowest Adjacent Grade on all sides and has more than 5ft to the Next Higher Floor.
What are "With Basement" rates?
200
All the documentation required for canceling a policy for building sold.
What is a cancellation request form signed by both the agent and insured & proof of sale, removal or total loss.
300
10/1/2008
What is the earliest map revision date to be eligible for the PRP Eligibility Extension?
300
Floodproofing Certificates must be certified by one of these people?
Who is a registered professional engineer or architect?
Or
Who is a licensed architect or engineer?
300
The lowest floor for rating when the building is on a slab with an attached garage that is not properly vented but contains no Machinery & Equipment.
What is the slab floor?
Or
What is C2a?
Or
What is the house floor?
300
Rates used to issue policies when producers fail to provide the required actuarial rating information.
What are tentative rates?
300
Contents covered in a basement regardless of zone or a Post-FIRM enclosure in specific zones.
What is an A/C unit portable or window type, clothes washer & dryer, and food freezer, other than walk-in, and the food in the freezer?
400
May be endorsed or rewritten as a PRP for only the current policy term.
What is a policy written as a standard B, C or X Zone policy and later found to be eligible for a PRP?
400
August 1, 2013
What is the mandatory use date for the 2012 version of the Elevation Certificate?
400
This floor is used for rating when the building is elevated and the enclosure and the garage are properly vented in zones other than V Zones.
What is the Next Higher Floor?
Or
What is the elevated floor?
Or
What is C2b?
400
Those properties that are a high flood risk because of peculiarities in their exposure to flooding & therefore do not lend themselves to preprogrammed rates.
What is Submit For Rate?
400
Zones that are not subject to the Post-FIRM enclosure limitations.
What are B, C, X, D, A, AO and A99?
500
Prior Zone: D
Map Revision: 2/14/2011
New Zone: AE
Eligible for the 2-Year PRP Eligibility Extension rated Zone X
This zone will be used for grandfathering at the end of the 2-Year PRP Eligibility Extension.
What is Zone D?
500
Elevation Certificates are not required for rating on these types of buildings.
What are Pre-FIRM buildings & buildings located in A99, B, C, X & D Zones.
500
The lowest floor for rating a building in a V Zone which has an unfinished enclosure that is less than 300 sq ft with breakaway walls & no Machinery & Equipment below the Base Flood Elevation.
What is the bottom of the lowest horizontal structural member?
Or
What is C2c?
500
The Replacement Cost Ratio for a building that is a business, that is worth $1,000,000 and has a policy with the maximum allowable coverage.
(Hint: V Zones)
What is 2?
Or
What is 50%
500
October 1, 1983
November 16, 1990
&
November 16, 1991
What are the designation dates for Coastal Barrier Resource Systems & Otherwise Protected Areas?
M
e
n
u