Indications
Equipment
Post Procedure
Settings
Capture
100

Indications for pacing.

What is heart rate under 60 bpm and hemodynamic instability?

100

Size of the single lumen central line in a standard CORDIS kit.

What is 8Fr?

100

Frequency of rechecks on a transcutaneous paced patient to verify capture is still present.

What is 30 minutes?

100

The starting settings for transcutaneous pacing

What is 80/80?

100

The two components of pacing capture

What is electrical and mechanical capture?

200

Common signs of hemodynamic instability in the setting of bradycardia.

What is hypotension or altered mental status?

200

Size of the single lumen central line included in a transvenous pacing kit.

What is 5Fr?

200

Methods to verify correct placement of transvenous pacer.

EKG, CXR, ECHO

200

Starting settings for transvenous pacer in a crashing patient.

What is emergency button?

200
Define electrical capture.

What is a QRS complex and T wave for every pacer spike.

300

Indications for transvenous pacing.

What is failure of transcutaneous pacing or prolonged need for transcutaneous pacing?

300
Difference between the standard single lumen central line and the transvenous pacer kit line.

What is clinching cap to sheath introducer port?

300

Transcutaneous pacing post-procedure medications.

What is IV sedation and IV analgesics?

300

Starting settings for transvenous patients in a semi-stable patient?

What is 80-5-3?

300

Define mechanical capture.

What is cardiac contraction following a pacer spike sufficient to produce a pulse.

400

Common clinical causes of bradycardia that may need pacing.

What is septal myocardial infarction, high degree AV block, overdose of cardiac medications?

400

Size of the balloon on the transvenous pacer wire.

What is 1.5 mL?

400

Steps to secure a transvenous pacing wire.

What is extend sterile wire cover, document pacer insertion depth, coil on chest and secure with dressing?

400
Documented settings for successful transcutaneous pacing.

What is 10 milliamps over the output when any beat is dropped?

400

recommended treatment when electrical capture is achieved but mechanical capture is not.  

What is pressors?
500

The clinical condition that should not be paced.

What is hypothermia?

500

Port on the pacing generator that the generator cable connects to. 

What is V or ventricular?

500

Method to secure transvenous pacing settings once capture is achieved.

What is lock the pacing generator?

500

Most common cause of failure of transcutaneous pacing failure?

What is poor pad placement?

500

Recommended steps to address electrical capture failure.

What is increase output, check pads, transition to transvenous pacing?