It's a Chemical Attraction
How Flexible is this Process?
Are you "Laser Focused"?
Hot Blooded
Wrapped Up with a Bow
100

You need to call this Code in the event of any chemical spill that cannot be cleaned up by the employee involved because the response required is beyond the training and PPE available to them 

What is Code Orange?

100

Case carts with dirty endoscopes need to have this placed on top of the case cart when taken to Decontamination.

What is a red or purple priority cone?

100

Eye protection must be worn during the operation of this type of laser

What are all lasers?

100

Triggering agents for Malignant Hyperthermia

What are inhaled anesthetic agents and succinylcholine?

100

Instrument trays should not exceed ____ pounds

What is 25?

200

Any spill that can be contained and cleaned up by the employee involved using the training and Personal Protective Equipment (PPE) available to them

What is a Minor or Incidental Spill

200

The maximum amount of time between precleaning and manual cleaning allowed before additional cleaning is required

What is 1 hour?

200

These are kept in a designated area and removed when the laser is not utilized. They are accessed only by those authorized and credentialed to operate the laser 

What are laser keys?

200

Malignant Hyperthermia (MH) is an uncontrolled release of intracellular ______ from the skeletal muscle

What is calcium?

200

The shelf life of a manufactured packaged sterile item is this

What is event related?

300

This document's purpose is to inform workers on how to handle chemicals safely and react to emergencies. 

What is the SDS (Safety Data Sheet) or the former term of MSDS (Material Safety Data Sheet)

300

When wiping the Olympus endoscope after a procedure, you wipe from the _____ to _____ end.

What is proximal to distal (clean to dirty) end?

300

This must be done to ensure proper beam alignment and firing of the laser at the start of each case, each time a handpiece is changed, and/or if the laser is moved from its stationary position 

What is a test fire?

300

The only medication that stops the release of intracellular calcium (Ca) from skeletal muscle sarcoplasmic reticulum and reverses malignant hyperthermia

What is Dantrolene (Ryanodex)?

300

These can be used during the processing and packaging of sharp instruments, especially if the instrument is peel pouched.

What are tip protectors?

400

This chemical is used for implant fixation in various Orthopedic and trauma surgery procedures but can cause hypotensive events or cardiac events in hypovolemic patients

What is Bone Cement or Methyl Methacrylate

400

This is the amount of Maximum Storage Time an unused endoscope has before it must be reprocessed.

What is 7 days?

400

These two things need to be placed on any door allowing access to the room where a laser procedure is being performed.

What are goggles and a laser warning sign (ANSI Z136.1-2014 DANGER or WARNING sign).

400

The location of the MH cart

What is Anesthesia Supply/Work Room?

400

This should be placed in an area within a sterilized package that presents the greatest challenge for air removal and sterilant contact. (Clue: more than one of these may be placed in a rigid container)

What is a chemical indicator?

500

This is the percentage of formalin used in the OR for specimens.

What is 10%

500

In addition to the patient identifiers, the type of procedure, date and time of procedure, the _____of the endoscope must be recorded.

What is the endoscope's serial number or unique identifier?

500

In the event of a laser accident or injury, notify your immediate supervisor, Employee Health and complete this

What is a Safety Event Report (SER or Midas)?

500

This organization tracks incidents of MH and will provide advice during a malignant hyperthermia incident

What is MHAUS?

500

Disposable wrapping should be checked for this before placing the sterile item on the sterile field.

What are holes, stains, and/or defects?

M
e
n
u