Oldie But a Goodie
Old dog New Trick
Highlight, Cut, Copy, Paste
Decisions, Decisions
X-ray Video
100

The Primary parts of a CR system is 

Cassette

Photostimuble Plate (PSP)

Plate Reader

Computer workstation

100

The two general categories of DR systems are referred to 

Indirect and Direct Capture

100

A graphic representation of a data set

Histogram

100

This uses a fluorescent (light producing) screen and a device that converts the light to electricity.

Phototimer

100

Flux Gain x Minification

Brightness Gain

200

The PSP Plate is made up of several layers, name these layers in order

Protective

Phosphor

Reflective

Conductive

Support

200

What are the two forms of indirect capture?

Charged Coupled Device

Xray Scintillator

200

The size of the _______ determines the resolution

Matrix

200

A hollow cell that contains air and is connected to the timer circuit via an electrical wire is known as

Ionization chamber or ion chamber

200

An expression of the degree to which the image is minified from input phosphor to output phosphor.

Minification Gain

300

This has a columnar phosphor crystals within the active layer resembling needles standing on end and packed together

Structured Phosphor Layer

300

The other indirect capture method also uses a scintillator with cesium iodide or gadolinium oxysulfide as the phosphor, a photodetector and a?

TFT array

300

The available grayscale and refers to the number of the shdes of a gray that can be displayed within a pixel is known as?

Bit Depth

300

AEC devices are equipped with _______ that allow the radiographer to adjust the amount of preset radiation detection values. 

Density Controls

300

A function of the Fluoroscopic unit that maintains the overall appearance of the fluoroscopic image by automatically adjusting KVP and/or MA

ABC - automatic brightness control

400

Silvery rare earth metal used as an activator for phosphor is known as

Europium

400

The direct capture method that avoids the extra step and the problem by not using a _____ and instead uses a ____.

Scintillator, photodetector

400

The range of exposure values to the receptor that produce an acceptable range densities for diagnostics purposes..

Exposure latitude

400

Shortest exposure time that the system can produce

Minimum Response Time

400

The combined result is an unequal magnification (distortion) of the image creating what is called..

A pincushion appearance
500

This is used to sense the light release from the PSP plate during scanning..

Photodetector

500

Amorphous Selenium make up the 

Photodetector

500

The range of exposures intensities that an image receptor can repsond to an use to acquire image data..

Dynamic Range

500

Maximum length of time the X-Ray exposure continues when using an AEC system..

Back-Up Timer

500

When operated in ________ ________ the voltage to the electrostatic focusing lenses is increased.

Magnification Mode

M
e