Main Screen
Tunnel Settings
Setup Navigation
Scan Arch Sensor Setup
Wrap Angle Window Settings
100

CAR@SCANARCH, SCANNING, CONVEYOR RUNNING, WHEEL@SCANARCH, WRAPS ACTIVE and Out-In Inclinometer angles are all types of these.

What is an indicator?

100

INCHES PER MINUTE shows this.

What is an indicator for speed of conveyor in inches per minute.  A calculated value based upon the inches per pulse cycle and the number of pulses from the conveyor movement.

100

Pressing the SCAN ARCH SENSORS, WRAP TABLES, REAR CONTROLS, VISUAL DIAGNOSTIC SCREEN, DS/PS INCLINE SENSOR SETUP, INCLINOMETER VALUE SCREEN, DS/PS MANUAL AND SETUP or VFD STATUS DATA _________ will take you to each of the screens you select.  

What is a button?

100

The ULTRASONIC TEST BUTTON does this.

What is converts values coming from the Scan Arch ultrasonic sensors to inches from "0" or inner conveyor rail. Used for testing sensors.

100

The Wrap Target Angle is the desired angle of the Wrap, the CURRENT ACTUAL X and Y DEG show the values of each axis as reported by the inclinometers, while the E-STOP NEG/POS ANGLE shows this.

What is the maximum angle reported by the inclinometer before the system sends out a panic stop?

200

CARS PER HOUR is number of cars going through in an hour, VALID CAR COUNT is number of cars inducted into the Wrap system, while the __________ COUNT displays the consistency of conveyor pulses.  

What is Pulse?

200

These two MIN/MAX values calculate the length of the car using the number of pulses from the conveyor movement while the Gate PE is blocked.  These values are then compared to determine a valid car is present.

What are MINIMUM AND MAXIMUM CAR LENGTH INCHES?

200

The amount of time the wrap needs to exceed the E-Stop angle before the system will send out a panic stop.

OVERANGLE DELAY 10 = 1S

200

These are the MIN and MAX distances from the sensor to the side of the vehicle to be considered valid.

What are DS/PS TOP/BOTTOM OUTPUT MINIMUM/MAXIMUM?

200

The two values (x and y) that describe the lower and upper value of the Wrap Angle Window.

What is NEG ANGLE and POS ANGLE?

DS X/Y NEG ANGLE, DS X/Y POS ANGLE

DS X/Y POS ANGLE, PS X/Y NEG ANGLE


300

DS/PS POS IN. displays the actual Wrap position in inches while this displays the targeted position.

What is DS/PS TARGET?

300

This value added to the SPACE BETWEEN CARS will yield the car full length value used in calculating the
number of cars per hour.

What is TYP CAR LENGTH INCHES?

300

The OVER ANGLE STOP DISABLE button does this.

What is the button that toggles the system’s ability to send out a panic stop in the event that the time set for the over angle is exceeded?


300

These are the distances from the Scan Arch to the inner rail of the conveyor guide.

What is DS SCAN ARCH TO WRAPS and PS SCAN ARCH TO WRAPS labeled DISTANCE SCAN ARCH TO WRAPS "INCHES"?

300

These buttons adjust the Wrap Y Angle window by negative or positive 1on both the minimum and maximum values.  

What is the ANG IN and ANG OUT buttons?

400

This button will take you to another screen where the user can enter setup values for the positioning control system.

What is the TUNNEL SETTINGS?

400

Pressing this button allows the operator to enter the number of inches between the pulses from the conveyor pulse generator as defined by the conveyor manufacturer. This value is used in conjunction with the Distance to scan arch values to trigger the wraps as well as providing the conveyor speed in feet per minute.

What is INCHES PER PULSE CYCLE?

400

In the event that  a recoverable fault has occurred, the user taps this button and the system will conduct a reset of the home position on the Lenze Inverter by moving the cam out to a predetermined position and then returning it to the home position.

What is the MANUAL HOME RST SEQUENCE button?

400

Numeric data display where the user will need to enter in the distance from the scan arch on the driver side or passenger side to the inner rail of the conveyor guide.

What is DRIVER SIDE and PASSENGER SIDE labeled DISTANCE SCAN ARCH TO INSIDE OF INNER RAIL "INCHES"?

400

The ADJUST FREQUENCY 0 - 10 button is a numeric data display where the user can enter in the  frequency that the cam will attempt to adjust the wrap arm, while the INCLINE ADJ. ENAB. button does this.

What is turns on and off the systems ability to adjust the wrap angle using the inclinometers? 

(disables inclinometers)

500

This hidden button behind the ICS logo requires what to get to the SYSTEM SETUP SCREEN NAVIGATION.

What is a password?

500

The CONVEYOR SIGNAL DEBOUNCE is this.

What is a numeric data display where the user can enter in the amount of time that the pulse from the conveyor movement needs to be either high or low to be considered a valid pulse.

500

This button returns you to the Main Screen.

What is the RET MAIN button?

500

The PHOTO EYE ANTIBNCE 10 = 1 SEC does this.

Data display where the user can enter in the time in seconds that the gate photo eye needs to be blocked or cleared for it to be considered a valid state.

500

The Wraps Active indicator means this.

What is the Wrap arm is not in home position and inclinometers are actively adjusting the cam based on position table and Inclinometer measurements.

M
e
n