Section 1: General
Section 2:Materials & Equipment
Section 3: Piping
Section 4: Drainage system
Section 5: Venting System
100
every fixture, appliance, interceptor, cleanout, valve, device or piece of equipment shall,
be so that it is readily accessible for use, cleaning and maintenance.
100
The term pipe and piping is used, it shall also apply to, (2 answers)
tube and tubing unless otherwise stated
100
Every caulked lead drainage joint shall be caulked to a depth not less than,
25 mm or 1"
100
Building drains and building sewers shall not be sized not less than,
What is 4"
100
A floor drain need not be vent if, (3 answers)
Trap size is min 3", trap arm is min 18", and fall of the fixture drain does not exceed the pipe size
200
A combined building drain shall,
not be installed
200
Screwed cast-iron water fittings shall not be used,
in a drainage system
200
T's can be extracted from these types of copper tube, (2 answers)
What is L & K
200
A horizontal branch serving 3 water closets will be this size
What is 4"
200
When finding the load on a circuit vent, the load on the ____ is not considered.
What is Relief vent
300
A plumbing fixture can not be installed in a room unless its, (2 answers)
lighted and ventilated
300
Every fixture shall be made of,
smooth, hard, corrosion-resistant surface free of flaws and blemishes that may interfere with cleaning
300
These types of copper tube shall not be bent, (2 answers)
What is DWV and M
300
When converting continues flow to fixture units, multiply,
L/s x 31.7 f.u's
300
When finding the load on a wet vent, _____ is not considered.
What is the last fixture served.
400
Every sanitary drainage system shall be connected, (3 answers)
to a public sanitary sewer, public combined sewer or private sewage disposal system
400
how man shower heads can drain to a floor drain?
6
400
A potable water system tested with air must be able to with-stand,
What is 700kpa for 2 hours without a pressure drop
400
This is the maximum permitted temperature to drain into a sanitary system.
What is 75 C
400
A relief vent is permitted to have up to _____ drain into it.
What is 6 f.u
500
Every length of pipe and every fitting shall be stamped with the makers name, weight or class or quality of product and,
Have its information visible after installation
500
What is the maximum temperature that a shower valve can be set to?
49 C
500
An air break shall be equal to, (2 answers)
What is 1" or size of the fixture drain or branch
500
This fixture can be directly or indirectly connected to a sanitary drainage system.
What is a drinking fountain
500
Fixtures are permitted to connect to the vertical portion of a circuit vent and additional circuit vent if they are, (3 answers)
no more then two fixtures, they are connected back to back, the f.u from each fixture do not exceed 1.5 f.u
M
e
n