Storm Drains
Drainage
Venting
Water
Mish Mash
100

You need to know this to size roof drains

Total square footage

100

The pitch of 3" pipe is

1/4" per foot

100

What is a crown vent

 A vent installed within two pipe diameters of the trap weir

100

What is the critical level of a vacuum breaker

6" above the fixture being served

100

what is the formula for finding the capacity in gallons in a cylindrical tank when given the dimensions in inches

D2" X Length" X .0034 = Gal

200

Semi continuous draining on a roof, computes to this

1 G.P.M equals 24 Square feet

200

When your draining 1 toilet to a sewage pump, what is the discharge rate

20 G.P.M

200

All building drains within a structure shall, at minimum have at least one full size main stack vent or a vent stack no less than

3" in diameter

200

What is the maximum temperature for hot water in a building 

130 degrees

200

How many gallons of water is in a cubic foot

7.5 gallons

300

You need to trap a roof drain when this takes place

Connects to a sewer

300

The independent laundry main drain shall connect to the building drain

 a minimum of 40 pipe diameters upstream and downstream of any soil or waste stack.

300

The vent extension through a roof shall be no less than and shall extend to a point

2" in diameter and extend 18" - 24"

300

The maximum distance of a hot water line before a recirculation line is needed

75 feet

300

How many branch intervals can you have before you'll need a relief vent

10 branch intervals

400

The minimum and maximum from the ground a secondary roof drain needs to drain

18" - 60"

400

Not less than a 1½ inch branch waste or waste outlet shall be provided to receive the fixture drain from a kitchen sink, which shall connect

independently to the sanitary drainage system.

400

Where frost closure is likely to occur, each vent extension through a roof shall be at least

3" in diameter

400

Whenever water pressure from the street main, service, or other source of supply is insufficient to provide flow pressures at fixture outlets as required under 248 CMR 10.14(2)(c)

A booster pump and pressure tank

400

When installing storm drains in a parking garage what is needed for protection

recessed into the wall and guard rails

500

Roof drain assemblies for use on sun decks, parking decks, and similar areas, normally serviced and maintained, may be

level with the deck and shall have an available inlet area not less than two times the area of the conductor to which the drain is connected.

500

Fixture unit values for continuous or semi-continuous flow into a building sanitary drainage system, such as from a waste pump, sewage ejector pump, or similar device that discharges sewage waste shall be computed on the basis of

two fixture units for each gallon per minute of flow

500

Piping not to serve as a wet vent would include

1. Kitchen sink

2. Garbage disposal

3. Dishwasher

4. Laundry

5. Any sink used for culinary purposes

500

What is the flow pressure of a kitchen sink (residential)

8 P.S.I

500

What is needed on all risers that feed a second floor with multiple fixtures

A full port ball valve with drain valves upstream