Policies
Building Science
Processes
Divisional Guidelines
SWPPP
100

Which Policy prohibits anyone from smoking a cigarette in a Power Field Office(even after a really hard day)?

No Smoking/E-Cigarette Use Policy.

100

Curtain wall has just started on a project. This meeting is held to review critical installation procedures and is also a Power Policy

Window School.

100

What is generally true of thermal bridging through structural members?

Concrete and steel balconies can both be thermally broken from a structure.

100

Are the Divisional Guidelines intended to be all-encompassing prescriptive documents for a given Division of work?

No.

100

Do Power Personnel develop the SWPPP?

No.

200

Per the Membrane Installation Policy, this representative is required to review and document initial installation and then periodic work in progress of any air, moisture, or vapor membranes.

Manufacturer's Technical Rep.

200

What project-specific quality plan is discussed at this on-site meeting?

Project Start-Up Meeting.

200

What is generally true about U-Values and R-Values?

Increased performance is represented by lower U-values and higher R-values.

200

When was the last major update of the Guidelines completed?

2023.

200

What does BMP stand for, as defined by the EPA?

Best Management Practice.

300

These structural elements need to be verified by both the responsible subcontractor and a professional surveyor [prior to erection of steel].

Anchor Bolts and Embeds.

300

This process is the time of the job where the architectural details and systems are defined and aligned with actual products.

Shop Drawing Submittal Process.

300

What considerations should the team make when installing a large area of roofing (>50,000sf)?

Having a third-party inspection program.

300

What document defines Power’s role with regard to the SWPPP?

The Owner Contract.

400

This is the minimum test procedure that should be performed if no testing procedure is specified. This test can be performed by the contractors’ labor or contracted to an independent testing company.

Hose Stream Test.

400

What tool is beneficial to get trades to react and respond to Quality-related issues/observations?

HammerTech.

400

Stack effect is a natural phenomenon in buildings that is caused by _____ and can create operational issues such as ______.

Building height and temperature difference; building pressure imbalances.

400

When the project has multiple finished flooring types what submittal is a best practice to request from the flooring contractor?

A listing of each flooring type with its RH and PH requirements listed.

400

What is one of the best tools to document the installation and repair/maintenance of BMPs?

A camera.

500

What is the percentage of masonry that can be installed on a project prior to Masonry School?

2%.

500

What set of design documents is the best practice to engage your quality support manager?

Schematic Design.

500

What device on a dry pipe system needs to be located inside, if possible, to mitigate the risk of an accidental filling of the dry pipe system and potential freeze-up?

Drum Drip.

500

When do SWPPP inspections have to take place?

(Hint: There are two answers!)

Weekly and after 0.50 inches of rainfall or rainfall equivalent precipitation.

M