The BACnet Flow Controller has these (3) operating modes
What is Local, 10 VDC BAS, and BACnet?
This distance is recommended between a HORD diffuser and laminar flow diffuser
What is 2 feet?
This ceiling panel type/style is recommended in boom location areas
What is the SCF
This action would compromise filter media when installing the filter
What is touching the media
This CE Price air purifier can be mounted in the ceiling or placed on the floor
What is Puraflo?
Up to this number of Fan Filter Units can connect to (1) Price wall mounted speed controller
What is 30?
This CE product is required to surface mount a non-flanged diffuser
What is HGMF framing?
This main feature can be found in the Ultrasuite but not the Hospital Grade Common Plenum
What is LED integration?
Filter loading is monitored with this face mounted device
What is the LED indicator?
Relative to a dental patient’s body, this is the location where a return grille should be installed
What are the patients’ feet?
This document is the location where you would find the max/full load amp information for a Fan Filter Unit
What is the FFU Submittal?
FRFD has these (2) airflow patterns
What is 2-way Full Radial, 1-way Half Radial
The Ultrasuite with no HEPA has a minimum plenum height as low as this number
What is 12”?
This port is used to measure plenum static pressure as well as sample aerosol concentration above the filter
What is the Aerosol Sample Static Pressure Port (ASSP)?
These three different air purification technologies can be used in the Price Room Air Purifier (RAP)
What is HEPA, BPI, an UVC?
This motor program is used when a fan filter unit is ducted and there is an upstream VAV device
What is the constant Torque motor program?
The correct airflow orientation of a Radial Flow Diffuser when installed near a fume hood
What is perpendicular?
These types of driver cabinets must be surface mount installed with louvered sides along horizontal
What is 600W and Lutron driver cabinets?
These two installation styles is possible with the FDM
What is exposed and recessed?
These air purification devices are ideal for use in pandemic-ready patient rooms
What is the CARES unit or Puraflo Dual-Outlet?
This wheel type can be used with both Constant Torque and Constant Flow motor programs
What is Forwards Curved (FC) wheel?
This airflow pattern is required in ISO 5 and cleaner cleanrooms
What is Unidirectional airflow
Defined in ASHRAE 170, one of these types of OR or Class 3 rooms shall provide HEPA filters in the terminal device
People have this general misconception about the MPPS when reading the filter efficiency rating
What is the most efficient particle size rather than it being the worst efficient
An occupancy sensor can be found on this Price air purifier
What is the CAP?