NFPA
Apparatus
Hydraulics / Pumps
Positioning
Inspections / Maintenance
100

According to NFPA® 1901, fire department pumpers should have a minimum pump capacity

What is 750 GPM
100
A master stream nozzle used to put out fires from atop the engine
What is a deck gun
100

FL= CQ²L

What is the formula for friction loss

100

When fire conditions are evident upon arrival, the driver/operator should place the apparatus in a safe position

What is includes an exit route for apparatus should a withdrawal become necessary

100

When conducting a walk-around inspection, who should the driver/operator talk to in order to get the MOST accurate impression of how the vehicle last operated

What is the Last person to drive apparatus 

200

Standard that specifies minimum portable equipment that must be carried on all pumpers

What is NFPA® 1901

200
A apparatus equipped with a fire pump, water tank, hose, aerial device, and ground ladders
What is quint?
200

In the formula for friction loss, the “L” refers to

What is hose length

200

a guideline for positioning apparatus at a fire scene

What is Attempt to position apparatus upwind of incident

200

In general, steering wheel play should be no more than approximately

What is 10 degrees in either direction

300
Standard for Fire Apparatus Driver/Operator

What is NFPA®1002

300
A specialized watercraft and with pumps and nozzles designed for fighting shoreline and shipboard fires
What is a fire boat
300

the following is a nozzle pressure of 50 psi 

What is a Solid stream nozzle (handline)

300

generally considered the safest position for apparatus placement should a structural collapse occur

What is Corners of the structure

300

Apparatus with air brakes are to be equipped with an air pressure protection valve that prevents air horns or other nonessential devices from being operated when the pressure in the air reservoir drops below

What is 80 psi
400
Standard for the Inspection, Maintenance, Testing, and Retirement of In-Service Automotive Fire Apparatus

What is NFPA® 1911

400

This piece of equipment is powered by gasoline or diesel and can power tools and lighting

What is a Vehicle-mounted generator

400

In a centrifugal pump, it dictates the volume capacity of the pump

What is the Size of the impeller

400

where a pumper should be positioned to supply a fire department connection most efficiently

What is As closely as possible to the water source

400

Engines produced after January 1, 2010 may be equipped with an exhaust after-treatment system

What is Diesel Exhaust Fluid (DEF)

500
Standard for a Fire and Emergency Service Vehicle Operations Training Program

What is NFPA® 1451

500

Apparatus are known as brush trucks, Aux, brush breakers, or booster apparatus

What is Wildland fire apparatus?

500

In multistage centrifugal pumps, the impellers are

What is identical and have the same capacity

500

Stage approximately one block away from the scene in their direction of travel and await further instruction

What is Level I staging

500

Reduce the possibility of an apparatus going into a slide during heavy braking 

What is function of anti-lock braking systems

M
e
n
u