What does LOTO stand for?
Lock Out Tag Out
The testing and verification of systems in a facility before introducing actual process materials, power, or live operational conditions.
Cold Commissioning
A construction project milestone that signifies all mechanical systems, equipment, and components have been installed, tested, and are ready for pre-commissioning, commissioning, and startup according to design specifications and project requirements.
Mechanical Completion
The initial planning phase of a construction project that happens before any physical building begins.
Pre-Construction
A perforated pipe installed underground to collect and divert excess water from soil or a building's foundation, preventing water from accumulating and causing damage.
Drain Tile
Where can you download Sunscreen?
Use a link to Sunscreen's webpage
A business or person that carries out work for a company as part of a larger project.
Subcontractor
What's wrong here?

Standing under a suspended load
What is our greatest resource at SOLV
THE PEOPLE!
Calculate the rock needed for a road
100' length
20' width
8" depth
1.5 Tons of rock/cubic yard
69.48 - 73 Tons
(depending where you round)
When does your OSHA 30 training expire?
OSHA 30-Hour certification does not legally expire, but individual employers, states, or cities may require refresher training every few years (typically 3-5)
This test uses an insulation tester and applies a high DC voltage to electrical equipment to measure the resistance between its conductors and ground.
Megger
A formal, written amendment to an existing contract that documents and approves modifications to the original scope of work, project timeline, or budget.
Change Order
What is this?
160k Motor Grader
What is this?

RTAC
Real Time Automation Controller
Where can you download Bluebeam for your company laptop?
Company Portal
Give the folder name or number where subcontracts and purchase agreements are stored on Sharepoint.
29. Commitments
What's wrong here?

In equipment blind spot
When capturing meeting minutes, what is the most important thing?
Accuracy
What class of electrical gloves should you be using to safety work around the stringwire?
Class 0 - rated for 1500v DC
A phase of plant or system startup where the actual "live" power is introduced to perform tests under real operational conditions, confirming the system's ability to function safely and efficiently as designed. It
Hot Commissioning
A detailed document or set of requirements that outline the technical details of a product or system, covering aspects like materials, design, software, hardware, performance, and functionality.
Tech Specs
A key electrical system facility that transforms voltage levels, switches circuits, and distributes power from generators to end-users.
Substation
What is this?

MPT
Medium Power Transformer
What folder number is progress photos in The Grid?
24
All subs and vendors onsite need to be ___ a ___?
Under a contract
Name 3 items missing from this fuel station needed to be in compliance

Spill kit, drip pan, fire extinguisher, eye wash, & secondary containment
What is the first thing we need to do when receiving a submittal?
Review the document
An unplanned event or situation with the potential to cause injury, illness, or damage, but which ultimately does not, often due to a slight change in circumstances, such as luck or quick action.
Near Miss
This test is a common method for measuring the ground resistance of an electrical grounding system by injecting a known current into the soil and measuring the potential drop at different points to determine the overall resistance.
FOP
Fall of Potential
Is an approved, fixed project timeline that serves as a reference point to measure progress and track performance.
Baseline Schedule
This study assesses how a site's water systems, including surface water, groundwater, and precipitation, will interact with a proposed project
Hydrology Study
A legal document issued by a carrier to acknowledge receipt of cargo for shipment, acting as a receipt for the goods, a contract between the shipper and carrier, and a document of title.
BOL
Bill of Lading
You/Employee need permission changes to Sunscreen, who do you go to?
Project Manager will put a ticket in to tech support
A written amendment that modifies the terms of an existing contract, most commonly in construction, to document changes in the project's scope, cost, or schedule
Change Order
Spot the OSHA violation

Spoils are within 2 ft of trench
Occurs once a month for everyone in the company to hear updates
Source Call
A safety standard for electrical safety in the workplace to protect workers from major electrical hazards such as shock, electrocution, arc flash, and arc blast.
NFPA 70e
This test measures the voltage of a power source, like a battery or solar panel, when no electrical load is connected, using a digital multimeter set to DC voltage.
VOC
Voltage Open Circuit
This is the sequence of project tasks that determines the minimum project completion time. Any delay to a task on these scopes directly delays the entire project.
Critical Path
This test determines the load-carrying capacity and integrity of deep foundation piles by applying loads and measuring their response, typically using hydraulic jacks and displacement sensors.
Pile Load Testing
Fiber optic cables are primarily made of two materials for their core, name one.
ultra-pure glass (silica) or plastic (polymers like PMMA)
How do you get admin access to download/update programs
Requested through the service portal (they won't approve programs they have not vetted)
A model where a construction company uses its own skilled labor and teams to complete specific scopes of work on a project, rather than subcontracting those tasks out.
Self Perform Work
What's the SWPPP violation?

Silt fence is not filtering water, dirty water flowing offsite
These are the 3 C's with servant leadership
Compassion
Character
Competence
What type of fire extinguisher should you use on an electrical fire
Class C
AC voltage test used to assess the insulation quality of medium and high voltage power cables and other high-capacitive equipment, such as rotating machinery. The test involves applying a low-frequency (typically 0.01–0.1 Hz) AC voltage to the cable, which is much higher than the normal operating voltage, to stress the insulation and reveal weak points or damage that could lead to in-service failure.
VLF
Very Low Frequency
A construction term meaning a project is sufficiently finished that the owner can begin using it for its intended purpose, even if minor work or a punch list of corrections remains.
Substantial Completion
A specific, target date within a contract when a project, like a power plant or construction facility, is expected to be fully operational and ready to generate revenue or deliver its intended service, having successfully passed all necessary testing and certification.
COD
Commercial Operating Deadline
A passive electronic or RF (radio frequency) device used during installation of underground cable to mark key locations and prevent accidental damage by excavators later on
Marker Ball
How many progress photos do the SOLV guidelines suggest to take per day?
50 per day
The pre-agreed hourly costs for labor and the direct costs for materials, plus a markup that a contractor charges a client for a project.
T&M Rates
Which MET station sensor has an issue?

Temp sensors (TBOMs)
This form of communication makes up for 55% of total communication
Body Language
This section of the PTP helps workers systematically identify hidden or less obvious hazards at a job site by prompting them to consider various forms of energy
The Energy Wheel
The flux of radiant energy per unit area (normal to the direction of flow of radiant energy through a medium). The SI unit of this is the watt per square metre.
Irradiance
A federally required document under the EPA's Oil Pollution Prevention regulation that details how a facility prevents, controls, and responds to oil discharges from reaching navigable waters or adjoining shorelines.
SPCC
This survey is a detailed, three-dimensional map of a property that identifies and measures all natural and man-made features, showing elevation changes and creating a 3D picture of the land for architects, engineers, and contractors. In construction
Topographic Survey
How cold is too cold to pull wire?
About 14 degrees Fahrenheit
A foreman asks a PE to order more material. What should be the PE's response?
Did you talk to your superintendent about this?
This is an event or factor that threatens a company's ability to achieve its objectives, potentially leading to financial losses, a damaged reputation, or even business failure.
Risk
This is an example of

Galvanic Corrosion
What are the two things that can be impacted anytime there is a change?
Schedule and Cost
A visual, color-coded grid used in risk management to prioritize risks by plotting them based on their likelihood of occurrence and the severity of their potential impact.
Risk Assessment Matrix
This occurs in a solar energy system when the solar panels (photovoltaic or PV array) generate more DC power than the installed inverter can convert to AC power, resulting in some energy loss and a flattened "peak" on the power production curve.
Clipping
An NPDES permit that sets the rules for controlling stormwater pollution from construction sites that disturb one or more acres of land, or are part of a larger common plan of development. The permit requires operators to develop a Stormwater Pollution Prevention Plan (SWPPP), implement control measures, and conduct site inspections to prevent pollutants like sediment from entering waterways.
CGP
Contruction General Permit
This document outlines the acceptable testing specifications for electrical power equipment and systems. This standard defines field tests and inspections for evaluating new equipment before initial energization
ANSI/NETA ATS
Acceptance Testing Specifications
Corrosion of dissimilar metals occurs when two different metals are in electrical contact within an electrolyte, such as water. One metal, the anode, becomes sacrificial, losing mass (corroding), while the other, the cathode, is protected.
Galvanic Corrosion
Where do you update your time off/POD week for the Midwest team to see?
Midwest Smartsheet Page?
A specific, pre-agreed amount of money paid for a contract breach, typically when actual damages are difficult to measure. They function as a reasonable estimate of potential losses, not a penalty, and are established in a contract clause before the breach occurs.
Liquidated damages
Spot the issue

Safety glasses are Ray Bans
What's the S.M.A.R.T. goal acronym
Specific, Measurable, Achievable, Relevant, and Time-bound.