Fun Facts about QPM
Math
Codes
Definitions
Chapter 7
100

Number of children Eric has

What is 9

100

1/2 x 22/33

what is 22/66 or 1/3


100

Sinks shall be provided with waste outlets a minimum of __________ inches in diameter.

What is 11/2"   418.2

100

The extension of a soil or waste stack above the highest horizontal drain connected to the stack.

What is stack vent. 202

100

name of chapter 7 of the Ipc code

What is Sanitary Drainage


200

Number of years we have been at this location

What is 18

200

number of tons of gravel needed for a ditch 97' long,

2' wide and 6' deep


what is 64.66 tons

97x2x6=1164 cubic feet

1164/27 = 43.11 cubic yards

43.11x 1.5 = 64.66 tons

200

Water closet bowls for public or employee toilet facilities shall be of the _______ type.

What is elongated 420.2

200

Any heating appliance or equipment that heats potable water and supplies such water to the potable hot water distribution system.

What is a water heater.

200

Exposed soil or waste piping shall not be installed above surfaces in _____ __________ __________ .

What is food service establishments.  701.8


300

Number of employees currently at QPM

What is 58

300

Number of 16" pieces of pipe you can get out of 20' stick of pipe

What is 15

20' = 240"

240/16 = 15


300

All water heaters shall be third party _________

What is certified   501.5

300

Any part of the piping system except a riser, main or stack.

What is a branch.

300

A primer is not required for solvent-cemented joints of PVC drain, waste and vent pipe and fittings provided the installation is a nonpressure application and the pipe size does not exceed _____ inches in diameter.

What is 4"   705.11.2

400

Who was Quality Plumbings first influential customer.

Bud Lawson of Rocky Waters Hotel.

400

Number of safety violations in this picture

What is 11

400

Whirlpool bathtub pumps shall be located _______ the weir of the fixture trap.

What is above  421.2

400

The unobstructed vertical distance through the free atmosphere between the outlet of the waste pipe and the flood level rim of the receptacle into which the waste pipe is discharging.

What is an air gap (drainage system)

400

Cleanouts on 6" and smaller pipes shall be provided with a clearance of not less than ______ inches

What is 18"  708.1.9

500

What contractor erected the current building we are in today.

McSpadden Construction

500

3 equal distances in 22' 1/2"

What is 88.16"

22' 1/2" = 264 1/2"  divided by 3

529/2 x 1/3= 529/6 =88.16

500

Gray water used for flushing water closets and urinals shall be ______

What is disinfected.  1302.6.1

500

A measure of the probable discharge into the drainage system by various types of plumbing fixtures.

What is a drainage fixture unit.  dfu

500

Indirect waste piping that exceeds 30" in developed length measured horizontally, or 54" in total developed length, shall be ______ . 

What is trapped.  802.2