FIRE DYNAMICS
VENTILATION
BUIDLING CON.
HOSE
LADDERS
100

What model includes the chemical chain reaction to explain the combustion of fire?

fire tetrahedron

100

T or F, ventilation operations must be coordinated with fire suppression crews?

True. Without coordination fire conditions can worsen. 

100

What building construction type is a light-weight, wood-frame structure?

Type V

100

What is the internal diameter of a 2 1/2" hose?

2 1/2 inches

100
Where should the tip be placed for a rescue?

base of the window sill

200

Two surfaces rubbing together creates friction, which generates what?

mechanical energy

200

A positive pressure fan inside a structure is an example of what types of ventilation? Mechanical or natural AND horizontal or vertical?

mechanical horizontal ventilaztion

200

What building construction type is ordinary construction?

Type III

200
Both attack and supply hose may be equipped with either threaded or nonthreaded ___________?

couplings

200
What distinguishing features indicates a roof ladder

folding hooks as a means of anchoring the ladder

300

What is the term for control of air and smoke through a structure?

flow path

300

List an action that disrupts flow path control?

breaking or opening windows/doors unnecessarily 

300

What feature of type IV construction helps prevent unseen fire travel?

lack of voids or concealed spaces

300

What is the higbee cut?

A notch on the coupling that allows threads to placed inline.

300

Name a reason that a ladder should be placed out of service.

Exposure to high heat, direct contact with flame, heat sensor color change, or failing an annual test

400
In order to burn, liquid fuels must what? Pyrolize, vaporize, or have a specific gravity greater than 1.0?

Vaporize

400

When using positive pressure ventilation in a multistory building, it is best to start on what floor

ground level (lowest point first)

400

What type of wall often obstructs firefighter's view of the entire roof?

parapet walls

400

What is hard suction hose used for?

drafting

400

The method chosen when removing a victim down a ladder depends on what?

if the victim is conscious or unconscious

500
When sufficient oxygen is available for combustion, a fire is said to be _________-limited.

fuel-limited

500

What is the purpose of kerf cut?

It reveals the presence of smoke or flame. It does not provide ventilation.

500

Why are fires in basements more hazardous than fires in other compartments?

There is limited means of ingress/egress and firefighters can find themselves unknowingly above the fire.

500

What is maximum recommended gallons per minute for a handline?

350 gpm

500

What must be in the locked position before adjusting or climbing an extension ladder.

the dogs (high and low, if applicable)

M