Dental xray and film equipment/
Radiation Protection
Radiation characteristics
Radiation History
Dental x-ray film
100

The PID (position indicating device) is an extension of

What is the tubehead?

100

which PID size is ideal for reducing the divergant x-ray beam

what is 16 inches ?

100

the overall blackness or darkness of a film

what is density?

100

An image or picture produced on a receptor by exposure to ionizing radiation

What is a radiograph?

100
  • Current fast radiographic film requires ____% less exposure time than the initial exposure times used in 1920.

98%

200

the name of the intraoral receptor holder that is disposable styrofoam

What is stabe (bite block)?

200

which style (shape)of PID is most effective in reduction of patient exposure

rectangular collimator

200

MODERN dental equipment are equipped with this kV setting

what is 60-70 kV?

200

The bavarian physicist who discovered x-rays in 1895

Who is William Roentgen?

200

what size film is ONLY  used for bitewing images

what is size 3 ?

300

the component part of the dental x-ray machine that allows movement and positioning of the tubehead

What is the extension arm?

300

what does ALARA stand for

what is as low as reasonably achievable?

300

the quality of the x-rays produced is controlled by

What is the kV or kilovoltage?

300

The first company to manufacture pre-wrapped intaoral dental films

Who is Eastman Kodak ?

300

the apex of the roots can be seen in this type of image or images 

what is periapical film(PA) and occlusal ?

400

a device used to hold and align intra-oral x-ray receptors in the mouth

What is a rinn or receptor holder?

400

when placing a lead apron for a panoramic image, this should be removed

what is the thyroid collar?

400

the quantity of radiation produced is controlled by which 2 factors

what are mA (milliamperage) and exposure time?
400

a form of energy carried by waves or a stream of particles

What is radiation?

400

Which radiograph would be taken to expose a side profile for an orthodontic exam 

What is cephalometric 

500

what is used to restrict the size of the x-ray beam to the size of an intraoral receptor

What is a collimator (collimating device)?

500

the maximum permissable dose (MPD) for dental radiographers per year

what is 50 mSv/year, .05 Sv/year, or 5.0 rem/.year?

500

the contrast of a radiograph is only affected by which control panel setting

what is kilovoltage (kV)?

500

what year did the federal standards begin for dental x-ray machines

what is 1974?

500

the invisible pattern of stored energy on the exposed film

what is latent image?

600

the name of the film holder utilized in root canal procedures

what is the EndoRay?

600

which type of PID produces the most background scatter

what is conical?

600

a low contrast film (with mahy shades of gray) is ideal for evaluation and diagnosis of

what is periodontal disease?

600

what did William Coolidge develop

what is the first x-ray tube?

600

which type of film is used to examine large areas of the mandible or maxilla

what is occlusal, (size 4)?

M
e
n
u