Decon
Prep
Medivator's
Sterilization
QA
100

The correct dosing of Prolystica detergent in Decon. 

What is 1/2 ounce per gallon of water?

100

This item must be placed in every item sterilized.

What is a chemical integrator?

100
what is a bean bag
IDK
100

Required to be performed weekly.

What is the sterilizer Leak test?

100

Required to be in the facility a minimum of 48 hours prior to use.

What is a Loaner tray?

200

The removal of visible soil and other foreign material.

What is cleaning.

200

The air flow direction required for the preparation room.

What is positive air flow?

200
Pre-cleaning, leak testing, cleaning, high level disinfection, drying, and storing is the proper sequence for.



What is processing flexible endoscopes?

200

The sterilization cycle only used in emergency situation to save life or limb.

What is Immediate-Use Steam Sterilization (IUSS)?

200

These documents provide health and safety hazard and risk information 

What is Safety Data Sheets (SDS)?

300

The reprocessing of intraocular instrumentation excludes this solution always.

What is enzymatic detergent?

300

The sterilization cycle for SOP 2064.

What is Cycle #4 (275/5/30)?

300

The minimum water inlet pressure for Medivator's.

What is 35 psi?

300

The sterilizer has successfully killed all bacterial spores in a biological test.

What is a negative BI test?

300

The agency that approves the disinfectants used on floors and walls in the Sterile Processing Service.

What is the Environmental Agency (EPA)?

400

Used to check soil residual on endoscopes.

What is the Channel Check test.

400

The largest operating channel of an endoscope.

What is the instrument channel?

400

Information regarding cleaning processes for endoscopes should be provided by.

What is the manufacturer IFU?

400

Positioned flat in the area least favorable to sterilization.

What is a biological indicator?

400

The system used to treat the final rinse water used for cleaning. 

What is deionization (DI) or reverse osmosis (RO)?

500

The process where soiled instruments are sorted, inspected and if necessary, disassembled.

What is the Decontamination process?

500

Used in ear surgery and for driving very small wires through the bone.

What is a Micro Drill?

500

Scope Buddy Plus Tubing used on a non-Olympus endoscopes.

What is universal tubing?

500

The only item ran on Temp. 275, Sterilization time 20". 30" dry time.

What is dental endo files?

500

Specialized clothing or equipment worn by an employee for protection against a hazard.

What is PPE?