Formulas
Evaporation
Mold
Fire
Water
100

If L x W x H of water = Cubic foot of water (CFW)

then

CFW x _.__ = gallons of water GW

GW x _.__ = Weight of Water

7.48; 8.34

100

At what relative humidity will hygroscopic material absorb excess water vapor?

60%

100

The process of removing contaminated materials in a manner that minimizes the spread and aerosolization of contaminants and debris.

Controlled removal

100

In areas where visual signs are not evident but smoke odors still exist, it is necessary to test for...

Smoke

100

Category 1 water is from a clean source with no substantial risk of causing...

Sickness or discomfort 

200

Total gallons of flooded water...

Ft3(CF) x 7.48gal/ft3

200

Many building materials will absorb excess water vapor and suffer damage, especially when air is allowed to remain above _____% relative humidity.

40%

200

Condition 1

An indoor environment that may have settled spores, fungal fragments or traces of actual growth whose identity, location, and quantity are reflective of a normal fungal ecology for a similar indoor environment.

200

Thermal fogging petroleum-based deodorizers excessively in a confined space can create what safety hazards?

-Possible explosion

-Respiratory irritation

-Slippery residues 

200

Category 2 water carries a significant degree of 

Chemical, biological, and physical contamination 

300

Submersible pump- Time required 

Total gallons / Pump lift rate

/ = division 

300

What surface temperature promotes the most rapid evaporation? 

80 degrees

300

Condition 2

An indoor environment that is primarily contaminated with settled spores or fungal fragments that were dispersed directly or indirectly from a Condition 3 area, and which may have traces of actual growth.

300

Smoke a soot are visible by-products of...

incomplete combustion

300

Category 3 water results from a grossly ____ or carries...

Unsanitary source; pathogenic agents 

400

Refrigerant formula 

Ft3(CF)/class = Pints per day (PPD)/Unit AHAM = #Units

400

_______  is the temperature at which air becomes saturated with moisture and can hold no more water vapor.

Dew Point

400

Condition 3

An indoor environment contaminated with the presence of actual mold growth, associated spores, and fungal fragments. Actual growth includes growth that is active or dormant, visible or hidden.

400

To remove high levels of protein odor from surfaces, ______ __________ is usually required for cleaning protein residues.

Wet cleaning

400

What are the "4 knows" of drying?

What's wet?

How wet is it?

Is it drying?

Is it done?

500

Desiccant Formula

Ft3(CF) x class/60 = CFM required/Unit CFM = #Units 

500

Which of these surface temperatures would have the fastest rate of evaporation?

30 degrees above dew point, the higher the better

500

The transport of contaminants in the air from a contaminated work area to an unaffected area

Cross contamination

500

Both PAH and soot particles have been reported to be ___________ to humans

Carcinogenic; thus proper PPE must always be worn

500

How do you obtain a "dry standard"?

Dry standard involves pre-loss moisture levels in the structure, and they can be found by locating unaffected materials in the structure and getting the target values from there