Exposure Factors
Filtration & HVL
Distance & Magnification
Equipment & AEC
Technique & Math
100

What are considered the prime exposure factors in radiography?

kVp, mA, exposure time, and SID

100

What is the primary purpose of filtration in x-ray production?

To remove low-energy x-rays

100

The relationship between SID and constant IR exposure is described by which principle?

The direct square law

100

High-frequency generators are preferred because they do what?

Produce a nearly constant kVp and higher output

100

A 15% increase in kVp is equivalent to what change in mAs?

100% increase (doubling)

200

Which radiographic parameter directly increases the number of x-ray photons without changing beam energy?

mAs

200

What does Half Value Layer (HVL) measure?

The thickness of material required to reduce beam intensity by 50%

200

The inverse square law states radiation intensity varies:

Inversely with the square of the distance

200

What is the main function of AEC systems?

Terminate exposure at the appropriate receptor dose

200

If mAs is changed from 20 to 10 due to a smaller patient, the x-ray intensity has:

Halved

300

Which exposure factor primarily controls the penetrating power of the x-ray beam?

kVp

300

HVL measurements are most commonly performed using which material?

Aluminum

300

What is the formula for magnification factor?

MF = SID / SOD

300

Improper patient positioning when using AEC most likely results in what?

Incorrect receptor exposure

300

Which two factors, when increased, reduce image receptor exposure?

Distance and filtration

400

Increasing kVp produces what effect on the x-ray beam?

It increases both the beam energy and IR exposure significantly

400

If filtration thickness increases, what happens to x-ray beam intensity?

It decreases

400

Image magnification increases when which factor increases?

OID

400

A compensating filter creates what type of exposure in body parts of uneven thickness?

Uniform exposure with a nonuniform thickness

400

If SID changes from 72 inches to 36 inches and the original intensity is 20 mR, what is the new intensity?

80 mR

500

Increasing mAs causes what change in beam quality and intensity?

No change in quality; increase in intensity

500

For x-ray tubes operating above 70 kVp, the minimum total filtration required is:

2.5 mm Al

500

What is the best way to minimize image magnification?

Long SID and short OID

500

What image characteristic improves when using a small focal spot?

Finer detail of image (Spatial Resolution)

500

Which technique would give the highest patient dose?

  • 90 kVp/200 mA @ 0.02 sec
  • 87 kVp/400 mA @ 0.02 sec
  • 74 kVp/300 mA @ 0.04 sec
  • 65 kVp/300 mA @ 0.1 sec

65 kVp/300 mA @ 0.1 sec