Excavations
Numbers
Confined Space
Air Monitors
OSHA
100

Name 1 trench box vendor.

United Rentals

National Trench Safety

Others

100

How often must a confined space entry form be completed?

Daily

100

One option for ventilation.

Confined Space Fans / Blower Fans

100

If alarm sounds, what should do immediately?

Get everyone out of the confined space immediately and call the Safety Team.

100

Where can you find the OSHA Construction Standards?

OSHA 1926

OSHA.gov

200

Access/Exit point must be within how many feet from work areas?

25 ft

200

The minimum distance (in feet) a spoil pile is required to be from the edge of an excavation.

What is 2 feet ?

200

Name the 3 roles of confined space entry.

Entrant

Attendant

Supervisor

200
Once the confined space air has been tested and determined to be safe for breathing, where should you put the air monitor?

Option #1: Attach to worker

Option #2: Place at working level

200

When should you contact an underground utility locator company ?

Before you begin digging the excavation

300

What is the proper slope for type C soil?

1.5 to 1

300

Required depth for access point to be established.

What is 4 feet?

300

Who is authorized to evaluate and identify confined space hazards and protection measures?

Confined Space Competent Person

300

Air monitor readings for safe air.

What is 0, 0, 20.9%, 0 ?

300

What is the minimum clearance distance equipment should be from powerlines?

Depends on the voltage. Check with power company for voltage and minimum clearance distance.

400

Name one way to test soil type.

Pocket Pentrometer

Roll Test

Assume soil is type C

400

How many pictograms are there in HAZCOM ?

9

400

What heights are we required to test air quality prior to entry with air monitor in a confined space?

all levels of a confined space

400

Safe oxygen levels in a confined space.

19.5% - 23.5%

400

If you contact a powerline, then what is the best course of action?

STAY IN YOUR SEAT

500

What type of soil are you allowed to bench?

Type B Soil

500

Name the requirements for 2ft, 4ft, 5ft, 6ft, and 20ft.

2ft = spoil pile

4ft = access point

5ft = Protection: Shielding, Shoring, or Sloping

6ft = fall protection

20ft = registered professional engineer

500

Confined Space definition.

1. Limited/resticted means of entry/exit

2. Large enough for worker to enter

and

3. Not designed for continuous human occupancy

500

L.E.L. Acronym 

What is Lower Explosive Limit?

500

What subpart of OSHA are the confined space standards found?

1926 Subpart AA

M