Fixed fire systems
General fire knowledge
Alarms
Lifesaving appliances
100

What are the 3 fixed fire fighting systems onboard?

Drencher system for main car deck

Dry pipe water mist system for machinery spaces

Wet pipe water mist for deck 1 thruster compartments, technical space and deck 4 crew mess

100

How many isolation valves do we have onboard for the fi-fi main? What are their purpose?

6. They are to maintain supply in the event of failure of any section of the piping (due to damage). Four on the car deck are remotely operated, two on the sun deck are manually operated.
100

What does the general alarm mean?

Go to fire stations (usually followed by a PA announcement.)

100

What is the capacity of the ESS composite unit?

150 person raft

200

How many drencher sections are there onboard? 

Where can they be operated?

There are 4 sections supplied by seawater from 3 pumps

From the DCS on bridge and the CCR

200

On what decks are the isolation valves located?

Deck 2 and deck 4 

200

What is the emergency signal for emergency stations?

7 short 1 long 

200

What are the SIS?

small inflatable slides. One is in the MES1 station and the other is in a lifejacket locker on the main car deck.

300

What is the capacity of the drencher pump?

230m3/hr

300

What is the capacity of the fire pumps?

88m3/hr

FiFi pump-5m3/hr @5 bar

300

What is the man overboard signal?

Three long blasts on the ships whistle and or 3 long rings on the general alarm followed by a PA announcement

300

How many additional liferafts do we have onboard, what is their capacity and where are they stored?

Two additional 100 person rafts installed on deck 4 and would be normally launched from the embarkation station. Additionally they can be launched manually from their cradle on deck 4. 

400
What does "wet pipe system" mean?


What pressure is the system always at?

The sections are always full of water, section valves open and system pressurized by 25 bar and ready for automatic activation in standby mode.

400

True or false-Fire pump #2 is automatically started

False. Fire pump 2 is in auto mode, and fire pump 1 is only manual start/stop

400

What does Schedule G mean? 

a non-specific threat has been received. 

400

True or false-according to our evacuation plan, if an emergency developed in dock while loading and an evacuation were to take place, passengers will be allowed to drive their vehicles off?

False. Vehicles will remain onboard until it is deemed safe for the passengers to return to the vessel for an orderly evacuation of all vehicles. 

500

True or false? Releasing the hi-fog system into the machinery spaces also activates the emergency stops related to that location.

True

500

Where are the fire pumps located?

FiFi pump 1 and primer pump-drencher room

FiFi pump 2 and priming pump-FiFi room

FiFi booster pump-technical space

500

What is schedule F?

What are the 2 stages of searching? 

A specific threat has been detected. An unconcealed search will be initiated in 2 stages. 

Stage 1: primary search -first passenger muster stations and escape routes are designated, cleared of passengers and then searched.

Stage 2: Secondary search to ensure all pax in muster areas and remainder of ship then searched

M