Hot Work
Working At Heights
Confined Space
SHE (General)
100

The person designated to inspect area of hot work being performed to watch for heat, slag, or sparks in case a fire starts. 

What is Fire Watch

100
Frequency at which personal fall protection must be inspected by the user. 

What is before each use. 

100

Person designated to stay outside the confined space while work is being performed to maintain communication with workers inside the space and have means to summon help if needed. 

What is an attendant (hole watch) 

100

What the acronym SHE stands for. 

What is Safety, Health, and Environmental

200

Equipment that is filled with an extinguishing agent specific for type of fire that is likely to occur in the approximate area of placement. 

What is a fire extinguisher. 

200

Working at height between these two heights does not require a permit if a JHA and SOP has been developed for the task. 

What is 4' and 20'. 

200

Must be conducted prior to entry into any permit required confined space and is done to ensure that are no toxic/flammable gases present and that there is enough oxygen present in the space. 

What is atmospheric testing. 

200

Controlling exposures for self and others. 

What is Safety? 

300

The amount of time continuous fire watch is required following any level 2 hot work activities. 

What is 1 hour

300

Working height at which a WAH permit is required no matter what.

What is 20 feet. 

300

Must be used by entrants to continuously monitor atmosphere inside confined space while work is being performed. 

What is Personal gas meters/monitors. 

300
The meaning of the acronym PPE. 

What is personal protective equipment. 

400

Amount of incremental time required for intermittent fire watch following the completion of continuous fire watch after level 2 hot work has been completed. (Every how many minutes)

What is every 15 minutes

400

Adequate anchorage points should be able to support this amount of this amount of weight per worker attached. 

What is 5000 lbs. 

400

Entry supervisor must notify them before entry into a permit required confined space in case emergency rescue is needed. 

What is the local fire department (designated rescue team) 

400

The meaning of the acronym EAP. 

What is Emergency Action Plan
500

Level of hot work being performed is unlikely to cause sparks, slag, or heat such as with hand tools, band saws, pipe threaders, etc.

What is Level 1

500

The ratio of vertical height to horizontal distance a ladder must be placed at to maintain safe positioning. 

What is 4:1 (1' away for every 4' high)

500

The required PPE for entry into any permit required confined space. 

What is a hard hat, safety glasses, safety boots, and a full body harness unless it would increase the risk. 

500
The meaning of the acronym CAR-AR.

What is Context, Action, Result-Or Alternative Action, Alternative Result. 

600

Level of hot work being performed is likely to produce sparks, flame, slag or heat. 

What is Level 2

600

Frequency of which scaffolds must be inspected during use. 

What is weekly. 

600
This document must be completed for every entry into a confined space and lists who in going in and coming out of the space at any given time during the work. 

What is a CS Entry and Exit Log. 

600
Designated area where employees gather in the event of a site evacuation. 

What is the rally point/muster poing/assembly area. (Physical location of site specific will work)

700

Used to cover non removable flammable hazards, to seal wall/ceiling/floor openings, or to protect contained flammable hazards (piping/storage systems) during hot work operations. 

What is fire resistant blankets/tarps. 

700
The three items that comprise fixed fall protection systems (barriers) on elevated work platforms/ladder/ and catwalks. 

What is top rail, mid rail, and toe board. 

700

All permit required confined spaces must be labeled with this lettering. 

What is Danger - Confined Space - Enter by permit only. 
700

This is a detailed overview of a job which includes each step of the work being performed, the hazards associated with them, and the control measures that are taken to mitigate risk. This must be completed prior to completion of any non-routine task. 

What is a Job Hazard Analysis. 

800

Persons from whom approval is needed to proceed with Level 2 hot work during normal business hours. 

Who is the Site Superintendent and the SHE Coordinator

800

A rescue plan must be prepared and made available when performing any work over this height. 

What is 13 feet. 

800

Confined space definition 1 of 3: Large enough so that a person can do this to perform work. 

What is fully enter. 

800

A category of waste materials designated as "hazardous waste", but containing materials that are very common including batteries, lamps, pesticides, and mercury containing equipment. 

What is Universal Waste? 

900

Permit level for work requiring the use of non-intrinsically safe power tools in a Class 1 or Class 2 electrically classified area. 

What is Level 2

900

The amount of lifelines required to be used (per worker) when working on high angle roofs. 

What is 2. 

900

Confined space definition 2 of 3: Must be a space that is not designed for this. 

What is continuous human occupancy. 
900
The four elements of a dust explosion. 

What is fuel source, ignition source, oxidizing agent, and confinement. 

1000

Meaning of the acronym LEL. 

What is Lower Explosive Limit

1000

The meaning of the acronym MEWP. 

What is Mobile Elevated Work Platform. 

1000

Confined space definition 3 of 3: Word(s) used to describe the means of entry/exit into a confined space. 

What is restricted or limited. 

1000

The reportable quantity of oil in the event of a spill to waterways or drains that lead to waterways. 

What is a sheen across the surface of the water? 

M
e
n
u