Work place safety
First Aid
National Building Code
Side Jobs 101
100

At what height does the Occupational health and safety require fall protection systems

10 feet or 3 meters

100

when using an Epi pen where should it be used on the individual and what end goes into the individual? Blue or orange

Blue to the sky orange to the thigh

100

What is the maximum allowed stair height according to the NBC

7-3/4"

100
On what stree did Side Jobs install its first Chainlink fence? - Summer 2022

range lake road

200

How often should fall arrest be inspected by both the employee and the company?

the employee is required to inspect there fall arrest before each use.

The employer is required to inspect the fall arrest annually

200

What Does the abbreviation ABC stand for in first aid?

Airways Breathing and circulation 

-a series of first checks to go through when you encounter an individual that is not responsive

200

According to the NBC what is the minimum height for a handrail

34In

200

What one client did we do three bathrooms for?

Kathy & Zabbey racher

300

What Class of fire extinguisher is required for an electrical fire.?

ABCDK

A Class C or ABC fire extenguisher
300

When giving CPR on an adult what does the Recross recommend for compressions and breaths in ?

30 Compressions and 2 breathes

300

What is the maximum allowed spacing between spindles on a handrail? according to the NBC?

4"

300

How many employees total has side jobs had.

28

400

Using our "Frame Scaffold" how many layers can you build up before the scaffolding must be tied off?

the third tier would need to be attached to the building unless outriggers are installed at the base layer.

the general rule by OHSA is

a free standing scaffold shall be considered safe when the total height is equal to or less than four times the minimum or least base dimension.

which gives us just over 2 layers of scaffolding freestanding 

400

You have found someone laying on the ground unresponsive What are the next steps in order?

step 1) perform a scene survey to identify any present hazards 

Step 2)determine whether or not the person is responsive

Step 3) open airway and check for breathing and circulation for a maximum of 5 to 10 seconds

step 4) start performing CPR and yell out to someone to contact 911 or do so when you are able

400

What is the minimum dimension for any one side of Bedroom egress window.

Unobstructed opening of not less than 0.35 m2 (3.77 ft2) in area with no dimension less than 380 mm (15 in). An opening of 380 mm (15 in) x 920 mm (36 in) or 592 mm (23.3 in) x 592 mm would satisfy both requirements.