Decontamination
Assembly
Sterilization
Sterile Storage
Standards
100

This is the first step in cleaning surgical instruments.

What is Point of Use Cleaning?

100

This recipe is required when assembling instrument sets.

What is a count sheet?

100

Our current incubators take this long to read a BI's negative reading.

What is 24 minutes?

100

This necessary step must be done before storing to prevent bacteria from entering the sterile package through condensation.

What is Cooling?

100

This agency sets standards for workplace safety.

What is OSHA

200

This machine uses cavitation and sound waves to agitate cleaning solutions, effectively removing hard-to-reach surfaces and lumens.

What is Ultrasonic/PCF cleaner?

200

Instruments with lumens must be inspected with this device to detect damage or debris not visible to the naked eye.

What is a borescope?

200

This sterilization method uses hydrogen peroxide gas plasma.

What is V-Pro Sterilization?

200

Sterile items must be stored at least these many inches from the floor.

What are 8-10 inches?

200

The standard that outlines the parameters for steam sterilization. (E.g., time, temperature, pressure)

What is ANSI/AAMI ST79?

300

OH NO! The PCF failed twice now!

What is call 55-8000?

300

This type of joint found in many surgical instruments must be lubricated with a water-soluble lubricant during Assembly.

What is a box lock?

300

This type of chemical indicator reacts to all critical parameters of sterilization and is considered the most reliable type.

What is a Type 5 indicator?

300

In our SPD, we currently have this many storage racks.

What are 114 racks?

300

According to AAMI ST79, these many air exchanges per hour are required in Sterile Storage areas.

What are at least 4 air exchanges per hour?

400

Instruments that are manually cleaned must be submerged in cleaning solution for this long.

What is per Manufacturers IFU?

400

Instruments made of this metal are usually identified by their blue color and light weight.

What is Titanium?

400

This is the coldest spot in the steam sterilizer.

What is the drain or bottom front?

400

The principle that sterile items should be used in the order they were sterilized is known by this acronym.

What is FIFO? (First In, First Out)

400

The agency that regulates how we dispose detergent and OPA bottles.

What is the EPA

500

These three enzymes are the main enzymes used in Decontamination to clean proteins, fats, and starches.

What is Protease, Amylase, and Lipase?

500

This term describes the amount of time that a CaviWipe has to stay wet on a surface to effectively disinfect.

What is Contact or Kill Time?

500

The full name of the spore inside the BI

What is Geobacillus Stearothermophilus

500

This term refers to sterility being maintained until a package is damaged or mishandled, rather than based on expiration date.

What is event related sterility?

500

The Joint Commission requires that hospitals follow these two primary bodies for Sterilization and processing guidance.

Who is AAMI and The CDC?