History of Spence
Direct & Pilot Operated Regulators
Miscellaneous
Control Valves & Steam Traps
Spence Literature
100

Identify the correct Spence Logo:

REFER TO WORKSHEET

B

100

What are the 3 essential elements of a regulator?

Restricting

Measuring

Loading

100

T/F : The customer will always provide enough and the right information forever.

False

100

In a reverse-acting control valve, the valve is an air-to-_________ design, fail-_________ design.

Air-to-Open

Fail-Closed

100

Where can you go to obtain a Spence Designer's Guide?

Spence Website or Spence Portal

200

True or False: In 1984, Spence family sold the company to Watts Industries

True

200

What is the most common place for a regulator to fail?

Disc/ Orifice

200

T/F : Spence only sells thermostatic and thermodynamic traps.

False - Spence also sells mechanical traps, the orifice trap, pump traps, etc..

200

Name the 3 types of actuators Spence sells for the Control Valve.

1. Pneumatic

2. Piston

3. Electric

200

Which 2 product documents should you open and have on-hand during a troubleshooting call?

1. Instruction Manual

2. Bulletin

300

In June 2021, the Walden, New York manufacturing facility closed and all production moved to ________________.

El Salto, Mexico

300

List 3 Direct-Operated Regulators:

D50A

D34

D, D2

N6

Series 2000

300

When considering control line placement, a rule of thumb to follow is to place the control line ___ to ____ pipe diameters downstream of any area of turbulence.

10 to 20

300

A steam trap is an automatic valve which discharges _________, ______ and ___________ from a system while trapping, or holding in, ______.

A steam trap is an automatic valve which discharges condensate, air and non-condensibles from a system while trapping, or holding in, steam.

300

To provide a quote for a Standard spence product, where do you go to check for a List Price?

Spence Pricebook

400

Identify which Regional Sales Manager is over the territory below:

REFER TO WORKSHEET

Orange= Mike Mulder

Blue= Neil Davies

400

Which Main valve type requires a condensate chamber?

E5

400

When you sell a pilot op regulator, what are the three main parts to be ordered?

1. Pilot

2. E-Main

3. Bends & Fittings

400

Extra 50 points if you can justify your answer!

T/F : If a Float Trap fails to remove air and non-condensible gases (trapping those gases), there is an increased risk of waterhammer.

True

+50 : If a float trap fills with air, then it won't allow condensate to fill it, raise the float ball and open the trap, so it fails closed. This causes condensate to backfill, increasing the risk of waterhammer.

400

Using the Series 2000 Instruction Manual, identify which Configuration of Series 2000 is a double-seat, reverse-acting valve:

Type 2050

500

When was Spence acquired by Emerson?

2019

500

What are the advantages of a direct-op regulator over a pilot-op regulator?

Direct-Op, compared to the Pilot-Op:
- Fastest responding
- More cost-effective
- Easier to maintain (simpler design)

500

Extra 50 points if you can justify your answer!

T/F : Control lines don't always need to slope down away from the pilot.

False

+50 : Sloping away from the pilot
- prevents condensate from collecting in the pilot
- maintains accurate pressure readings.

500

Extra 50 points if you can justify your answer!

If the Dura-Flo bucket trap isn't primed during install, will the trap fail open or closed?

Closed

+50 : Without submersion in water, the bucket will never float up to open the trap.

500

Using the Series 2000 Instruction Manual, tell me what Key 7 and Key 12 are.

Figure 8 

7 = V packing assembly 

12= frame locking nut

M
e
n