What is the most cited steel citation
Lack of fall protection
Above what height must fall protection be provided to iron workers by the employer and worn by the employee?
15'
Rigid frames must have what % of bolts installed prior to disconnecting from the hoist.
50
Name 2 exempted steel structures not covered by the steel erection standard.
Electrical towers, communication towers, tanks.
Above what height does an iron worker need to tie off?
30'
Diagonal bracing must have how many wrench tight bolts installed prior to releasing the hoist
1
What two paperwork items must be given to the steel erector by the controlling contractor
Cure cert, Anchor bolt modification approvals
What is the area called where fall protection doesn't need to used between 15' and 30' in the air
Controlled decking zones
When installing double connections how many bolts must remain intact while making the second connection.
1
Who is responsible for adequate ground access on the site during steel erection
The controlling contractor
Decking/Floor
When erecting open web or bar joists with lengths over 40' they must be able to be _________ bolted.
Temporary of field
What is the maximum number of steel members that can be lifted tied to each other
5
What other job other than deckers are not required to use fall protection between 15' and 30'
Connectors
A person must be a _________ person to train workers in Christmas treeing, connecting, CDZ procedures
Qualified