Steering
Suspension
Accessories & Attachments
Electrical
~Mystery~
100

All machines require wheel (or track) chocks and lock out / tag out when performing steering system work. An articulated steer machine also requires this

Properly installed and rated safety bar 

100

This component controls lateral side to side movement of the axles

Pan hard rod

100
True or false: all cutting edges are reversible to have more than one wear life

False

100

Electrical components are typically rated by this

Voltage and Amperage

100

The term for an injury caused by oil under pressure being embedded under the skin due to either close proximity to a leak, or cracking open a system without properly depressurizing first

Hydraulic Injection (serious injury)

200

This will determine the turning radius of the front tires in relation to the rear tires on a machine with two pivoting frame sections

Location of the articulation point

200

This controls the ride height of the cushion hitch 

Linkage rod length on the levelling valve

200

These 3 organizations govern the standards for building and repairing ROPS and FOPS

SAE, ISO, OSHA
200

This type of circuit has multiple paths for current to flow, sometimes referred to as a current divider circuit

Parallel

200

Both a flow meter (hydraulic) and ammeter (electric) work on the same principle, they must be connected to a circuit in this configuration

Series

300

A flow divider (control valve) on an articulated haul truck has this purpose in the steering circuit

Prioritize flow to the steering circuit over flow to the hoist circuit

300

This must be compensated for when charging an accumulator

Temperature

300

These protect the shanks from wear and damage when digging into the ground

Teeth or Points

300

These are connected in parallel between the CAN-HI & CAN-LO 

120 ohm terminating resistors 

300

This term describes how much a lubricants' viscosity will change with a change in temperature

Viscosity Index (VI)

400

The minimum number of drive circuit related pumps on a large hydrostatic machine

Three. 2 hydrostatic, and at least 1 charge.

400

With the bail down, the cushion hitch is in this position, and bowl is doing this

Lockdown. Loading.

400

On a new rope, this type of damage can lead to a weak spot and reduce the working strength of the rope

Kinking

400

After installing a splice clip this procedure must be done to complete the repair

Solder and Heat shrink

400

This test may be performed to help determine internal wear in a hydraulic pump

Flow loss test or Oil leakage test

500

The number, and names, of all the steering functions on a motor grader 

Three; Front wheel steer, Articulation, and Wheel Lean

500

This suspension system allows for considerable movement, but the component which gives it it's name does not

Rubber block

500

This type of fire suppression agent is designed for class A, B, and C fires

Monoammonium phosphate (dry chemical)

500

This is the term for a panel illuminated by a single light source carried along thin plastic cores with a polymer optical cladding sheath.

Fiber Optic

500

When starting a troubleshooting (hydraulic, pneumatic, or electric) process, a technician should generally begin with this component.

Source of energy (Battery, Pump operation, Accum charge)

M
e
n
u