Cleaning Equipment
Sterilization Quality & Indicators
Asepsis & Sterility
Packaging & Shelf Life
Steam Sterilization & IUSS
100

This washer uses mechanical, thermal, and chemical actions to clean instruments.

What is a washer-disinfector or decontaminator?

100

This indicator monitors sterilizer effectiveness by testing non-pathogenic spores.

What is a biological indicator (BI)?

100

This term means the absence of pathogenic microorganisms.

What is asepsis?

100

An instrument set must not weigh more than this to prevent injury and allow proper drying.

What is 25 pounds?

100

IUSS stands for this: 

What is Immediate Use Steam Sterilization?

200

This cleaning device uses sound waves and tiny bubbles to remove soil.

What is an ultrasonic cleaner?

200

A biological indicator result should be this if sterilization conditions were met.  

What is negative? 

200

This term means the absence of virtually all microorganisms.

What is sterility?

200

Shelf life of sterile items is based on this type of event, not time.

What is event-related shelf life?

200

Items processed by IUSS should be transported directly to here.

What is the point of use?

300

The process that creates microscopic bubbles that implode to clean instruments.

What is cavitation?

300

A biological indicator must be included with every load that contains this type of item.

What is an implant?

300

Asepsis helps prevent infection, but this process completely destroys all microorganisms including spores.

What is sterilization?

300

Sets heavier than 25lb require longer what?

What is dry time? 

300

True or False: IUSS items can be stored for future procedures.

What is false?

400

Water temperature during cleaning should follow this source’s instructions.

What is the detergent manufacturer’s IFU?

400

If a biological indicator is positive, all items processed since the last negative test must be this.

What is recalled and reprocessed?

400

True or False: Sterility and asepsis mean the same thing

FALSE 

400

Loaner or device set weights and methods should always follow this source.

What is the manufacturer’s IFU?

400

The same cleaning and decontamination processes must be followed according to this reference.

What is the manufacturer’s IFU?

500

Hot water makes blood harder to remove because it does this to proteins.

What is denature or coagulate them?

500

The biological indicator test should be performed at least this often.

What is weekly (or per facility policy)?

500

This sticky buildup of bioburden on instruments prevents cleaning solutions from working properly

What is biofilm?

500

Handling, moisture, and airborne contaminants are examples of these types of events

What are event-related factors that affect sterility?

500

IUSS must use this type of FDA-approved sterilization container.

What is a rigid, enclosed container?