Identify the overall width and depth of grade beam GB2.
254mm x 1830mm
S2.2
Identify the size of concrete block used to construct the elevator walls.
190mm STD block
S2.3, S2.4, S2.5
Provide all of the details that describe column C4.
HSS 178 x 178 x 6.4
S2.3
What is the design live load for the 3rd Floor?
2.4 kPa uno
S2.4
Identify the sheet you will find enlarged plan Stair B 3:04.
A6.2
Identify the spacing for the 406mm diameter piles where a double pilecap occurs.
1218mm or 1220mm
S2.1
Identify the type and sizes of driven concrete piles.
P1 = 305mm dia
P2 = 356mm dia
P3 = 406mm dia
S2.1
Provide the size of the beam holding up Level 01 along GL B between GL 8 and GL 9.
W610X101
S2.2
What is the max aggregate size required for the masonry grout/core infill?
10mm max
S1.1
Identify the width of the barrier-free washroom in Men's 2:210.
1520mm
A7.1
Identify the types and quantity of CIP concrete piles.
CIP1 (406 dia x 8m) 5
CIP2 (406 dia x 11 m) 4
S2.1
How does lintel L1 differ from L2?
L1: 4 courses - 190mm x 790mm
L2: 3 courses - 190mm x 590mm
S2.5
Identify the size of the OWSJ specified to support the roof between GL G and GL H.
550mm deep OWSJ
S2.5
What is the size and gauge of the typical steel deck?
38mm - 22 gauge
S1.1
Identify the longitudinal section number and sheet number.
Building Section A
A4.1
What is the thickness of the concrete for the typical sump pit?
150mm
S7.1
What is the size of the bond beam and description of the reinforcing used at the third-floor level of the elevator?
190mm bond beam c/w 1-15M continuous
S5.3
Identify the type and size of the elevator hoist beam.
W200x21
S2.5, 1/S5.3
What is the code standard used to fabricate and erect structural steel in this project?
CSA STD CAN/CSA-S16.1
S1.1
Identify the quantity of roof drains in this project.
9
A2.4
Identify the typical distance from the centre line of the roof anchor to the edge of the parapet.
2000mm