Trouble Shooting
Prescribing
Settings
Maintenance
Hodge Podge
Final Jeopardy
100

This Alarm is related to kinks in the Arterial line or poor arterial access flow.

What is the Low Arterial Pressure alarm?

100

This model Tablo machine has a Minimum Dialysate flow rate of 50ml/min

What is the Tablo PRO+ machine?

100

This number represents the total amount of Bicarb a patient on Tablo experiences.

What is Total Buffer?

100

This disinfection cycle is required at the end of each day's use.

What is a heat disinfection?

100

TRUE or FALSE

Tablo will AUTOMATICALLY include manual and scheduled saline flushes into the fluid removal goal via changes in UFR

What is TRUE

200

This Alarm is due to increased pressure as the blood is going into to the patient. This may be caused by kinks or poor venous flow.

What is the High Venous Pressure Alarm?

200

A dialysate flow rate of 300ml/min represents Tablo's minimum or maximum flow rate

What is Tablo's Max Dialysate flow rate?

200

This is the range of Sodium that Tablo can deliver.

What is 130-145?

200

Tablo requires this type of disinfection once every 7 days and it takes 7-9 hours.

What is a Full Chem?

200

Per Tablo's User Manual, How often does Tablo require Chlorine and Chloramine testing?

What is before every treatment and every 8 hours during treatment?

300

This alarm happens during blood return or rinse-back when the Big red clamp or saline clamp is engaged

What is the Saline Clamp or Red Clamp Error?

300

When Dialyzing a large patient using the largest dialyzer, the highest DFR and the highest BFR, what is the only other option to improve clearance?

What is increase treatment time or duration of treatment?

300

This setting allows a nurse to deliver a set amount of saline to the patient on a specified time interval throughout the treatment.

What is a scheduled Saline Flush?

300

Cleaning the dialyzer connectors and dialysate caps are a part of this type of maintenance.

What is Routine maintenance?

300

          DAILY DOUBLE!!!!

Tablo's requirements for water temperature and pressure are 5-32 degrees Celsius and ______PSI

What is 30-80 PSI?

400

This alarm is triggered when Tablo senses a discoloration in the used dialysate line. It may be elevated bilirubin or blood.

What is the Blood in Dialysate alarm?

400

Tablo has 3 treatment type options.  IHD, UF Only and ______

What is Sequential Dialysis?

400

This setting limits how long the blood pump can be stopped before Tablo prohibits blood return.

What is the blood clot timer?

400

What is the name of the disinfectant that is used to perform Tablo's weekly chemical disinfection process?

Minncare HD

400

Conductivity and PH testing were a standard for every dialysis treatment. Tablo doesn't require this testing because Tablo has_________

What are 2 independent Conductivity sensors? 

500

DAILY DOUBLE!!!!!!!

This alarm is caused by a Sensor failure in the top door of the dialysis compartment of the machine that determines blood in dialysate.

What is a Blood Leak Sensor Failure alarm?

500

A very sick patient in the ICU on multiple pressors may require an extended therapy. What extended therapies can Tablo deliver?

What are SLED and PRO+ (PIRRT or 24 hour therapies)?

500

This device is used to save alarm limits and patient prescription.

What is the Patient key?

500

This type of disinfection takes 90 minutes and is used between patients that are Hep B+ or Hep status unknown.

What is a Quick Chem?

500

These are 2 methods of treating hypotension using Tablo during a hemodialysis treatment.

What are:

-give a saline flush -or-

-stop fluid removal  -or-

-decrease fluid removal goal

500

This is often called The Achilles Heel of Dialysis

What is vascular access?