T:slim
Infusion Sets
Control IQ
Mobi
Miscellaneous
100

Minimum amount of insulin needed in the cartridge AFTER the tubing has been filled to complete the load process

What is 80 units

100

This infusion set does not require a cannula fill

 What is TrusSteel

100

Target treatment range for Control IQ

112.5-160 mg/dl

100

The minimum amount of insulin needed in the cartridge AFTER the tubing has been filled to complete the load process in Tandem Mobi pump

What is 30 units

100

The number of personal profiles that can be programmed in a Tandem pump

What is 6

200

The number of air bubbles that should be removed from cartridge prior to filling with insulin

What is 2-3 big air bubbles

200

This infusion set comes with a 6mm cannula requires a 0.3 unit cannula fill 

What is Autosoft XC or Autosoft 90

200

 3 things does changing the correction factor affects

reduces constraints on Basal modulation, user given boluses are more impactful, automatic correction boluses are more impactful

200

The green pump status light indicates this on the Mobi

What is basal rate delivery

200

This helps optimize Dexcom/Pump connectivity

1-Wear pump with screen face out with t:slim

2-Wear pump on same side of body as Dexcom sensor with t:slim and Mobi

300

This alert will occur if a user taps “Bolus” but does not complete/deliver a bolus or does not use the back arrow to return to the home screen 

What is the "incomplete bolus" alert

300

Name one benefit of tubing

Freedom to disconnect, opens up more infusion set options, wearability (short vs long with adhesive sleeve and pump clips), smaller site/less likely to rip off

300

Extended boluses can be set for this many hours while CIQ is on

What is 2 hours

300

The Tandem Mobi has an IPX rating of 28, which means it is water resistant for how many feet and hours?

What is 8 feet deep for 2 hours

300


The difference between an Alert and an Alarm on the pump



Alerts: notify user about things that may require additional action or acknowledgment (Low insulin, Low power, incomplete bolus, Max bolus, Incomplete load sequence)

Alarms: Notify about actual or potential stopping of insulin. Requires action to resume deliver (Resume Pump, Low Power, Empty Cartridge, Cartridge Error, Temperature, Altitude, Occlusion).  Respond quickly. 

400

If necessary, you can get the pump to register more units have been added to pump cartridge by doing this

What is going through the entire Load Process (must tap change cartridge and fill tubing)

400

One reason you would switch someone to the Autosoft 30 infusion set

(Name one) Bent cannulas, leaking insulin with a 90 degree set, scar tissue, improve absorption

400

The treatment value at which a patient would recieve an automatic correction bolus AND how often these can occur

Predicted to be over 180 mg/dl in 30 minutes

Once an hour/an hour from any previous bolus

400

3 ways a bolus can be initiated with the Tandem Mobi system

Quick Bolus Button on pump

Bolus calculator on Mobi app

Entering override bolus in the app

400

The approved insulins that can be loaded into pump

What are Novolog (Aspart)/Humalog (Lispro)

500

After a cartridge change, the Insulin Level Indicator on the pump home screen displays an estimate of the amount of insulin in the cartridge as depicted by a + sign in front of a preset number. How many units must be delivered before the plus + sign disappears and the insulin level will display?

What is 10 units

500

True or false: the 5 inch tubing for Mobi is interchangeable between infusion sets

False-only comes with Autosoft XC infusion set

500

This happens when a patient's pump loses Dexcom connection

CIQ will stop adjusting insulin and pump will deliver insulin as programmed in personal profile, CIQ will automatically resume when pump receives Dexcom readings again.

500

True or false: The Tandem Mobi system requires internet connection, cell service, and bluetooth connection for use

True, but only bluetooth is required after initial setup to run the pump

500

Name one troubleshooting step for fixing lack of data in t:connect/Mobi apps and/or connectivity issue between phone and pump

1- Restart phone

2-Make sure app is updated/if it is, delete and re-install app

3-Unpair/Re-pair phone to pump

4-Disconnect from WiFi/or connect to WiFi (whatever is not currently the case)