Heavy Construction
Therm/Moisture and Roofing
Builder and Architectural
Int and Ext Finishes
General Specialties
100

This type of pile is used to form a continuous wall to resist horizontal pressures resulting from earth or water loads.

What is Sheet pile?

100

This is the permeability rating that building code often require vapor barriers to be.

What is .5 or less?

100

This is the minimum gauge sheet metal for steel sliding doors face panels should be constructed with. 

What is 14 gauge?

100

This type of screw is used to fasten drywall to wood studs.

What is W-screw?

100

This is examples of visual displays.

What is presentation boards, tack boards, building directories, etc?

200

This type of waterfront facility serves the same general purpose as a seawall but is constructed with relatively thin wall.

What is Bulkhead?

200

These materials should be inspected during the insulation submittal inspection. 

What is 

Composition

Thickness

U-Value requirements

R-Value requirements?

200

This is the type of glass that contains ferrous iron admixture that absorbs much of the energy of the sun.

What is heat-absorbing glass?

200

This type of special plaster additive is used to extend the plaster setting time.

What is Retarder?

200

This is what the suction inlet should be for a sump pump.

What is between 3 and 6 inches(75 and 150mm) above the sump bottom?

300

This is the primary purpose of a compaction pile.

What is to increase soil density?

300

This is something you should verify when inspecting loose fill blown-in insulation.

What is the insulation bulges past the studs by 1/2 to 1 inch?

300

This is where the label must be permanently affixed on a fire-rated door.

What is on edge of door and on doorframe?

300

This is how many days you must allow concrete to age prior to painting. 

What is 30 days?

300

This is the minimum number of fasteners that should be used to permanently install cases(cabinets) to floors or walls.

What is minimum of 2 anchors for each case?

400

These are the components of the timber bridge superstructure. 

What is 

Girders/Stringers

Decking/Flooring/Tread

Curbs and Handrails?

400

When inspecting roof sheathing you must verify that each panel is bearing on this number of rafters or trusses.

What is at least 2 rafters or trusses?

400

This type of glass is held together with plasticized polyvinyl resin butyl.

What is Laminated?

400

This is the measurement the color pin nails should driven for predecorated gypsum board installation. 

What is 8 inches on center along the edges?

400

This is the adjustable range controls temperature for primary water heaters.

What is 90 to 160 degrees Fahrenheit (32 to 71 degrees Celsius)?

500

These components of the substructure of a bridge, are usually 2 feet longer than the width of the roadway or trestle.

What is caps and sills?

500

This is the overlap on all joints when placing double layer of underlayment.

What is 2 inch overlap on horizontal points and 4 inch overlap on all edge joints?

500

This is the flame spread rating accordion doors should have.

What is not more than 25?

500

This is the commonly used sized panels used in the suspended ceiling systems. 

What is 2 X 2 and 2 X 4?

500

This is the check for that should be completed when inspecting toilet and shower partitions.

What is the location of the wall brackets?

M