MR Safety
Emergency Responses
Fire and Life
Medication
Mystery spot
100
The door to the scan room defines where this "line" is located.
What is the 5 Gauss Line
100
Emergency medications are kept in these locations.
What are at the nurse's stations:in the black cart (190) and in the cabinet next to the sink (180)
100
Overhead page code information is located on this.
What is your safety card?
100
Syringes are permitted to go unlabeled under these circumstances.
What is when they are drawn up for immediate use?
100
This type of storage container is strictly prohibited, and supplies must be removed from them promptly upon delivery.
What is corrugated cardboard?
200
This zone includes the reception area.
What is zone 1?
200
We respond to medical emergencies by doing this.
What is calling 911? and calling on-site physician
200
China Basin keeps a stocked isolation cart in this location.
What is the elevator room?
200
Contrast and saline flush are considered medications and must be stored in this type of facility.
What is locked at all times? Temp monitoring
200
This acronym helps in the event of a fire.
What is RACE? Remove, announce, contain, extinguish
300
UCSF uses these types of contrast media for MR exams.
What are Gadavist, Eovist, and Ablavar?
300
Oxygen tanks should be taken out of circulation when they reach this level.
What is less than 1000psi?
300
In event of an evacuation, this is our meet up point.
What is outside Philz coffee on 4th street?
300
Contrast media must be disposed of in this type of container.
What is a black hazardous medical waste bin?
300
Caring, Healing, Teaching, Discovering
What is the Medical Center Mission?
400
The UCSF Gadolinium policy allows administration with a GFR above this.
What is 40?
400
This device would be used in event of a cardiac arrest in CT at China Basin.
What is an AED?
400
Staff can see if a device has been checked for safety by looking for this.
What is a clinical engineering sticker? (blue even years, orange odd)
400
A patient's preferred language can be found in this location.
What is in the header of their chart?
400
2 times, every time.
What is proper patient identification?
500
MR safety training, venipuncture competency, MR competencies, and contrast administration competency are performed on this schedule.
What is annually?
500
The department EAP and go bag are located here.
What is the front desk?
500
A yellow clinical engineering sticker indicates that equipment is maintained by this party.
What is a third party vendor?
500
Iodinated contrast media may be administered to patients with a GFR above this level.
What is 30?
500
Adequate hand hygiene, surface disinfection, use of PPE, and safe injection practices.
What are standard precautions?
M