Sensible heat can be described as

Heat required to bring about a change of measurable temperature

100

What are the 3 parts of the flame on the oxygen/acetylene torch?

Inner cone, Outter cone, Tail

100

What is the 4th step in the sequence of operations for a 90% furnace?

HSI is energized

100

Flame Rod

A small diameter stainless steel rod on a gas furnace used to sense flame rectification by being placed in the flame

100

What size should the return air duct be?

As a big or bigger

200

Latent Heat can be described as:

Heat required to bring about a change of state

200

Oxygen/acetylene equipment has two hoses: the oxygen hose is ______ and the acetylene hose is_____. (what colors)

Green, Red

200

What is the 7th step in the sequence of operations of a 90% furnace?

Indoor Blower motor starts

200

Manometer

A pressure measuring tool that can measure low pressure in inches of water column

200

A high efficiency gas furnace will not stay in operation. The unit runs for approximately 5 minutes and then shuts down by the main furnace controller. What is the first thing to check?

Air Filter or Air flow

300

Specific heat can be described as:

The amount of heat required to change 1 pound of matter 1 degree F

300

The oxygen side regulator should be adjust to what PSI?

20 PSI

300

What is the first step in the sequence of operations of an Oil Furnace

Call for heat

300

Sensible Heat

Heat that can be measured by a thermometer.

300

Your servicing a 90% furnace that doesn't have properly sized duct work (the ductwork is sized too small) What are possible longer-term problems to having an improperly sized duct. 

lower heat exchanger life. Prone to cracking more easily.

400

The freezing point of water is zero degrees using what scale?

Celsius

400

How far should the oxygen tank be opened?

Fully

400

What is the 3rd step in the sequence of operation of a 90% furnace

Pressure switch closes

400

Primary Air

Air drawn into the gas burner to mix with air. As the air fuel mixture comes out of the burner, secondary air is added from the surrounding air and is ignited

400

What blower speed is most commonly used for the heating mode on a furnace with a multi speed motor?

Low

500

DAILY DOUBLE

What are the temperature scales that are used? (Name 4)

Fahrenheit, Rankin, Celsius, Kelvin 

500

How far should the acetylene tank valve be opened?

1/4 turn

500

How many BTUs are required to change 3 pounds of ice at 30 degrees to 3 pounds of water at 212?

975 BTU/H

500

Intermittent Pilot

A pilot burner that only operates when there is a call for heat

500

How many BTUs are required to change 1 pound of ice at zero degrees to 1 pound of steam at 220?

1314 BTU/H