APU
engine systems
gernerator trouble shooting
Random
Troubleshooting
100

what are the tempature limits for the -10 apu egt.

max peak-732

10 sec max 710

max cont-649

01-75paa-2-4-4 wp 5 pg 5. 

100

what causes a chips light and where is the light. 

on the engine annuciator panel.. and metal shards. 

100

what is the output voltage of the engine generators and the apu generator

60 kva for engines on ground and apu, 90 kva in air. 115/208 vac

01-75pac-2-13-1 

wp 3 pg 1. 

100

what pub can you find the part number for the landing light assembly

01-75pac-4-7 fig 5 pg 1 

100

 No warning light in either

pilot or copilot Landing Gear

Control Lever handle

LANDING GEAR CONT VALVE

circuit breaker opened.

01-75psc-2-13-1-2

200

what pub  and wp can you find the insert removal for the apu gen removal. 

01-75paa-2-4-4 wp 9 

200

What is required after pulling the sync box?

Fuel Governor Pitchlock Checks


01-75PAC-2-13-1-2 wp14A-20

200

how do you perform the generator feeder fault reset procedures 

turning off the motor or apu and then rotating the cat eye on the sup panel. 


01-75pac-2-13-1 wp 3 pg 12. 

200

how long does it take to run a full engine de-ice check? 

160 seconds. 

01-75pac-2-13-1-2 wp 15 pg 6 


200

during pre flight pilots notice, half of the red lights arnt working what is the probable cause and fix?

red lights are wired in series the light at the start is likely disconnected. 

300

where is the apu fire detector relays? and how many are there

forward load center, 5

01-75pac-2-13-1-2 

300

Used in troubleshooting oil cooler flap actuator gripes, name this breaker?

Flight Idle Stop (corresponding to engine)


01-75pac-2-13-1-2, WP 5-7

300

apu generator is not powering buses what are the suspected faults. 

defective acr in supervisory panel. defective transfer relay. 

300

what is the test voltage of the engine anti ice system test.

11 vac

01-75pac-2-13-1-2 wp 15 pg 2 

300

after doing swings on a/c 414 during the next pre flight ground ac does not work and landing gear warning horn is going off what is the probable cause?

ground air sensing cb left pulled. 

01-75pac-2-13-1-2 wp 9 

400

how many sensing element make up the apu fire detection system. 

2

01-75pac-2-13-1-2 wp 17 pg 1 

400

Used to troubleshoot speed sense control gripes, name this tool?

ACE Jumper

Wire jumper connecting pins A, C and E


01-75pac-2-13-1-2 WP 7-13

400

what is the generator mech fail device 

AC Generator Mechanical Fail Device. Insertedin the alternator stator assembly is a mechanicalfailure warning device which consists of a soft copperstrip embedded in, but insulated from, the stator frame.The strip is connected to a warning indicator circuit sothat a ground is provided to light the associated (red)GEN indicator on the center instrument panel 

wp 3 pg 2

400

how many modes does the td system have? what are they?

start-limiting mode

temperature limiting mode

temperature controlling mode

01-75pac-2-13-1-2 wp 10 pg 2

400

you have power distibution over under voltage issues fix them but now hyd pumps are not working what is the probable cause/fix?

hyd pump motor protector relay triggered need to reset. 

verify voltage going to motor. 

500

where can you find the functional check for the apu fire detection and extinguishing systems.

01-75pac-2-13-1-2 

wp 17 pg 8 

500

How many terminal points are on a feather button switch?

20 

01-75pac-2-13-2-2 pg 251

500

what are the under frequency protection relay in the sup panel?

the acr( auxillary control relay)

wp 3 pg 12

500

how many rack over heat sensors are there on a ep-3e 

41

01-75eps-2-8 wp 19 pg 3 

500

apu has low egt indication 

apu thermo couple is going out. 

M
e
n
u