electrical
what do I do
what's my symptoms
100

customer complains unit isn't working at all.

You find 120 volt power but no 24 volt

what part has most likely failed

The transformer 

100

units blower motor has high amperage draw, static pressure is .8 inwc, unit says its max is .7 inwc.

The duct work is proper, and evaporator coil is clean, you find the return side has the highest of the two for static pressure

what should I do next

Check Return Grill

100

The furnace is going out on high heat 

The blowers amperage is high

The air supply is slightly weak

what's my problem

Air restriction

200

customer complains unit is not responding at all

you find unit has 120 and 24 volt power. you find out you can jump wires to make unit work

What part most likely has failed

thermostat 

200

unit is making a horrible loud noise. This is only when the blower is on. The unit shakes aggressively 

What should I do next (two things)

Check The squirrel cage of the blower to make sure nothing is on it and check bearings of motor

200

Burnt wires on high volts side

breaker is tripped

Whats my problem

grounded out high volt hot wire

300

Customer complains that they have had 3 companies out and none have found the problem

you notice that the unit runs perfectly fine for the first 2 start ups but on the 3rd you notice the blower motor shuts off before inducer motor and flame

what part has most likely failed

The control board

300

The unit has been shutting off after running for only 5 or so minutes

The flame is blue with orange tip, nothing changes when the blower comes on. after running for 5 minutes the unit shuts off.

what should I do next

OHM across or check volt for high temp limit switch

300

motor only spins sometimes

makes weird noise 

motor has low and high voltage

what's my problem

The bearings

400

customer complains that unit would try to run but now wont.

you find unit is in a hard lock out, you reset power

the unit turns on the inducer motor but nothing after. the inducer motor gives off .9 inwc

the pressure switch calls for .5 inwc 

what part most likely has failed

the pressure switch

400

Unit is in hard lock out. you find the flame rolls back when unit comes on unit confirming cracked heat exchanger

what do I do next

LOCK OUT TAG OUT!!!

400
wires just dangling

nothing hooked to either plenum

customer left basement door unlocked

what's my problem  

someone stole it

500

customer says unit is not blowing any air

you find that the blower motor has 120 volt power and 24 volt call. the motor is a PSC motor the motor its self is fine 

what part most likely has failed

The capacitor 
500

Unit isn't working at all

you find that 3amp fuse on board is popped. you put a resettable fuse 

what should I do next

unhook low voltage wires and test each one to find short
500

unit has soot everywhere

the burners are warped

what's my problem 

too much gas pressure let through gas valve 