WIRES
BREAKERS
OUR SERVICE
GROUNDING/BONDING
"SMOKE'EM IF YOU GOT 'EM"
100

COLOR OF A GROUNDED CONDUCTOR

WHAT IS WHITE?

100

THIS IS A BREAKER THAT ALLOWS FOR TWO BREAKERS TO ONLY TAKE UP ONE SPACE.

WHAT IS A TANDEM? 

WHAT IS A PIGGYBACK?

100

"OMW" NTIALS STAND FOR WHICH PHRASE AND BUTTON YOU SHOULD BE PRESSING ON YOUR HCP APP EVERY SERVICE CALL 

WHAT IS " ON MY WAY "?

100

GROUND RODS SHALL BE AT LEAST THIS FAR APART

NEC: WHAT IS 6 FEET?

TRU-LINE : WHAT IS 8 FEET?

100

 SMOKE DETECTORS MUST BE INSTALLED INSIDE THESE ROOMS ?

WHAT IS A BED-ROOM ?

200

THE MINIMUM LENGTH OF FREE CONDUCTOR AT JUNCTION BOXES IS.

WHAT IS 6"?

200

THE MINIMUM SIZE MAIN BREAKER FOR A SINGLE FAMILY RESIDENCE IS.

WHAT IS 100AMP?

200

WE PUT THESE ON OUR FEET WHEN WE ENTER A HOME.

WHAT ARE FLOOR SAVERS?

200

METAL WATER PIPES SHALL BE BONDED TO THIS.

WHAT IS THE MAIN SERVICE EQUIPMENT ENCLOSURE?

200

THE CODE REQUIRES SMOKE ALARMS TO BE REPLACED AFTER THIS MUCH TIME,EVEN IF THEY STILL APPEAR TO FUNCTION.

WHAT IS 10 YEARS ?

300

When wiring with Romex (non-metallic sheathed cable), the sheath should extend at least ___  inside the box and beyond any cable clamp.

WHAT IS  1/4 inch ?


300

THIS TYPE OF BREAKER HELPS PREVENT ELECTRICAL FIRES IN RESIDENCES.

WHAT IS AN ARC FAULT CIRCUIT INTERRUPTER?

300

THE ULTIMATE SERVICE CALL IS RAN USING THE P.A.C.E SYSTEM , WHICH STANDS FOR ?

WHAT IS PREPARED,ARRIVED,CONNECT AND EXCUTE.

300

THIS IS THE MAXIMUM LENGTH FOR A CSST BOND.

IFGC: WHAT IS 75 FEET?

300

SMOKE ALARMS MUST BE INSTALLED AT LEAST THIS DISTANCE AWAY FROM SUPPLY REGISTERS.CEILING FANS, BATHROOMS W SHOWERS TO PREVENT NUSINACE ALARMS.

WHAT IS 3 FEET ?

400

An Arlington arc shield/guard, or more accurately, an box extender, is required when an electrical box is set back too far from the wall's surface, specifically when it exceeds a ___ inch gap in non-combustible walls or any setback in combustible walls. This is to ensure the electrical device is properly supported and to prevent arcing or shorting, especially in metal boxes where the screws can contact the box.

WHAT IS 1/4"  ?

 *In non-combustible walls or any setback in combustible walls. This is to ensure the electrical device is properly supported and to prevent arcing or shorting, especially in metal boxes where the screws can contact the box.

400

THE MAXIMUM HEIGHT OF A CIRCUIT BREAKER IS.

WHAT IS 79"?

400

WE PRESENT THESE  WHEN SOMETHING IS NOT WORKING AND REQUIRES TESTING

WHAT ARE DIAGNOSTICS?

400

A CONCRETE-ENCASED ELECTRODE IS COMMONLY CALLED BY THE NAME OF THIS INVENTOR.

WHO IS UFER?

400

IN NEW CONSTRUCTION HOMES IT IS REQUIRED THAT SMOKES BE HARDWIRED 120V AND ____________.

WHAT IS INTERCONNECTED?

500

WHAT IS  MINIMUM SIZE COPPER WIRE SERVING A POOL RING/ BOND OR HOT TUB BOND.

WHAT IS #8?

500

BREAKERS ARE NOT PERMITTED TO BE INSTALLED IN THIS TYPE OF ROOM.

WHAT IS A BATHROOM?

WHAT IS A CLOTHES CLOSET?

500

WE USE THESE TO QUALIFY OUR CUSTOMERS.

WHAT ARE DISPACTH FEES?

500

THIS IS THE MINIMUM SIZE GEC FOR A 150A SERVICE.

WHAT IS #6?

500

IN A SLOPE CIELING CEILING,SMOKE ALARMS SHOULD BE INSTALLED WITHIN THIS DISTANCE OF THE PEAK BUT NOT DIRECTLY AT THE APEX.

WHAT IS WITHIN 36'' (3 FEET) HORIZONTALLY OF THE PEAK ?