Load Process
Infusion Sets
Control IQ
T:connect
Miscellaneous
100

Minimum fill on the t:slim

What is 95 units

100

This infusion set does not require a cannula fill

What is TruSteel

100

Target treatment range for Control IQ

112.5-160 mg/dl

100

One benefit of t:connect reports

1-shows basal rate modulation

2-shows automatic correction boluses AND normal food/correction boluses

3-shows time in range and basal/bolus %

4-Shows when CIQ suspended pump for lows

5-Shows time CIQ is in use

6-When Sleep/Exercise activities are being used

7- Dexcom tracings/trends

8- Pump settings including basal that is programmed vs basal that has been delivered

9- Logbook shows what basal rate was delivered by CIQ hour by hour

10- Alert/Alarm settings

100

Pump is watertight for this deep and this long

What is 3 feet for 30 minutes

200

The number of air bubbles that should be removed from cartridge prior to filling with insulin

What is 2-3 big air bubbles

200
This infusion set comes with a 6mm cannula requires a 0.3 unit cannula fill 

What is Autosoft XC or Autosoft 90

200

Minimum number of hours sleep activity should run for

5 hours (should not use for naps)

People using sleep overnight on average have TIR > 80% during that time frame

200

Name one troubleshooting step for fixing the lack of data in t:connect and/or connectivity issue between phone and pump

1- Restart phone

2-Make sure app is updated

3-Unpair/Re-pair phone to pump

4-Disconnect from WiFi 

200
The number of personal profiles that can be programmed

6

300

If necessary, you can get the pump to register more units have been added to pump cartridge by doing this

What is going through the entire Load Process (must tap change cartridge and fill tubing)

300

This infusion set is manually inserted at a 30 degree angle

What is the VariSoft

300

Extended boluses can be set for this long while CIQ is on

2 hours

(If CIQ is off, can be set for up to 8 hours)

300

True or False: Alerts and Alarms showing up on t:connect app can be cleared from phone

FALSE: they must be cleared from pump

300
This helps optimize Dexcom/Pump connectivity
1-Wear pump with screen face out

2-Wear pump on same side of body as Dexcom sensor/transmitter

400
The approved insulins that can be loaded into pump

What are Novolog (Aspart)/Humalog (Lispro)

400

One reason you would switch someone to the Autosoft 30

(Name one) Bent cannulas, leaking insulin with a 90 degree set, scar tissue/improve absorption

400

The treatment value at which a patient would recieve an automatic correction bolus AND how often these can occur

Predicted to be over 180 mg/dl in 30 minutes

Once an hour/an hour from any previous bolus

400

What you can do in mobile app if patient says they are getting annoyed by alerts/alarms showing up on phone

Turn off Pump Alerts and Alarms 

AND/OR

Turn off CGM Alerts and Errors in "Settings" 

400

One thing that can be found in current status menu

1- Last bolus

2- Current basal rate being delivered

3- Current profile settings 

4- Dexcom info (i.e. when sensor was last started, how Transmitter battery is doing)

5- If patient is using mobile app/has a connection

6- What profile is active in pump

7- If CIQ is on or off

500

Fill estimate volume reads this many units less than it was initially filled with each new cartridge

Usually 40-60 units less until 10 units have been delivered on new cartridge; then it counts down by 5 until you get to 40 units left and then counts down by 1 unit at a time. 

500

Process by which a patient would fix stubborn high BGs if they have already corrected with the pump

check ketones, give injection, change site regardless of when it was last changed

Check for loose connection, air in tubing, etc.

500

This happens when a patient's pump loses Dexcom connection

CIQ will stop adjusting insulin and pump will deliver insulin as programmed in personal profile, CIQ will automatically resume when pump receives Dexcom readings again.

500

If a patient has not been using their app for a long time, they should do this to ensure data uploads to the cloud prior to clinic appointments 

(name one) 

1-Open app 48 hours prior to appointment

2-Download pump via T:connect on computer

500

The difference between an Alert and an Alarm on the pump

Alerts: notify user about things that may require additional action or acknowledgment (Low insulin, Low power, incomplete bolus, Max bolus, Incomplete load sequence)

Alarms: Notify about actual or potential stopping of insulin. Requires action to resume deliver (Resume Pump, Low Power, Empty Cartridge, Cartridge Error, Temperature, Altitude, Occlusion).  Respond quickly. 