Furnaces
Burners and More
Other Stuff
100

List the four categories of gas fired furnaces based on flue gas temperature and pressure

Category I, Category II, Category III, and Category IV

100

What is the purpose of the orifice located on the gas manifold?

The orifice meters the gas into the burner.

100

What is the difference between a a 90 percent furnace with a sealed combustion system and a typical 90 percent furnace?

Sealed combustion units require combustion air to be piped in from the outsid

200

Explain the difference between a Category I furnace and a Category IV furnace?

A Category I furnace operates with a high temperature, negative pressure vent. A Category IV operates with a low temperature, positive pressure vent.

200

Why is it not a good idea to drill out orifices in the field?

The hole must be drilled precisely. Errors can result in dangerous burner malfunctions

200

 A Category I furnace operates with a

 High-temperature, negative-pressure vent.

300

List the five furnace cabinet configurations.

Up-flow, down-flow, horizontal, low boy, multi-position

300

What is the purpose of the burner venturi?

The shape of the venturi causes the gas and air to swirl as they pass through the constricted opening, mixing them together

300

How does air flow in a standing-pilot, natural-draft system

It relies on heat to increase the buoyancy of the air to pull air into the combustion chamber and force flue gases into the proper vent

400

What changes were made in furnace design to achieve 80% efficiency?

Removed standing pilot light, flatten and serpentine heat exchangers, and added induced draft blower.

400

What may happen if the gas stream through the in-shot burner does not pass straight inward and hits the side of the venturi?

This causes poor ignition and even explosions

400

 A stainless steel coil that is built like a refrigeration coil and allows a high-efficiency unit to move into the 90+ percent efficiency range is called:

 A recuperative coil

500

What is the difference between an 80% efficient furnace and a 90% efficient furnace?

90% furnaces have an extra recuperative heat exchanger that condenses water out of the flue gas.

500

What factors determine the size of a burner orifice?

The size of the orifice is determined by three factors: the specific gravity of the gas, the heat content of the gas, and the required BTU/hr rating of the burner.

500

What precautions should be taken when using an unvented gas heater?

The primary concern for unvented space heaters is the oxygen depletion and possible carbon monoxide buildup.