Flames and More
Hot Surface Ignitors
Gas Valves & Regulators
Furnace Operation
Furnace Operation2
100

The operating sequence to light the main burners on an intermittent pilot system is

The pilot valve and spark igniter are energized, the pilot flame is proved, and then the main gas valve is energized.

100

 Why should the heating element of a hot-surface igniter NOT be touched when installing a replacement igniter?

The igniter will burn out where you touched it.

100

 The atmospheric pressure and the adjustable spring pressure work together to balance the gas regulator's:

Outlet gas pressure

100

 The operation of modern induced-draft equipment is normally controlled by

 An electronic board

100

The typical start up sequence for a hot surface ignition system is

Combustion blower prepurge, igniter energized after a delay, gas valve energized after a delay, flames sensed, indoor blower energized after time delay.


200

 How long is an ignition trial on a direct spark ignition system?

4 to 21 seconds

200

Hot-surface igniters are made of

Silicon carbide.

200

Combination gas valves used on standing pilot furnaces combine:

Pressure regulation, a solenoid valve, and pilot safety.


200

When the room-temperature setting is reached, what components are opened?

Thermostat and gas valve circuits

200

 Two-stage gas furnaces can use single-stage thermostats that offer:

A timed transition from low to high fire

300

 If pulsed DC current is not present in the flame rod, what is the effect on the gas valve in a direct spark-ignition system?

 The valve will remain closed.

300

Which of the following statements accurately describes silicon carbide?

It is brittle and will break easily.


300

Why do solenoid-type valves pose a problem for some types of burners?

 Solenoids open and close too quickl

300

 In a traditional gas furnace with a standard combination gas valve, what controls the gas valve?

The heating thermostat

300

Two-stage furnaces require:

2 stage gas valve

400

 What type of flame proving do direct spark ignition controls use?

Flame rectification

400

Hot-surface igniters typically operate on ____ voltage


120V

400

Some furnaces use two automatic shutoffs that are mechanically in series to provide additional safety. What type of valves are these?

Redundant valves

400

What does the furnace board do on most modern furnaces?


 It controls the ignition, safety, and blower operation.

400

Modulating thermostats have both ________ control

proportional and integral

500

How does the flame rod sense the flames in a flame rectification circuit

 The flame changes the AC voltage to pulsed DC current

500

 Hot-surface igniters typically operate for a _________________ per day 

few minutes 

500

 Why do direct spark ignition furnaces and hot-surface ignition furnaces require redundant gas valves?

 For safety since there is no pilot safety solenoid

500

 The major electrical loads in an induced-draft hot surface ignition furnace are

Induced-draft blower, indoor fan motor, the gas valve, the igniter.

500

Modulating furnaces often have a pressure transducer to measure the

Draft pressure.